TK-5810
(
BG
)
/5810H
(
BG
)
66
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
5. Balance
adjust
*2
1) Adj item: [BAL]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[
✳✳✳
]
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [Balance]
Deviation
meter
LPF : 15kHz
HPF : OFF
2) Adj item: [Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Rear
panel
ANT
[Panel
tuning
mode]
[PF3]
[PF4]
[PC test
mode]
[ ],[ ]
Make the demodu-
lation waves into
square waves.
6. Maximum
Deviation
adjust
*2
(Wide)
1) Adj item: [FMWD]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[
✳✳✳
]
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [Max
Deviation (Wide)]
Deviation
meter
LPF : 15kHz
HPF : OFF
Detector: ±PEAK/2
2) Adj item: [Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
4000Hz
±50Hz
(Narrow)
1) Adj item: [FMND]
Adjust:
[
✳✳✳
]
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[
✳✳✳
]
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [Max
Deviation (Narrow)]
Deviation
meter
LPF : 15kHz
HPF : OFF
Detector: ±PEAK/2
2) Adj item: [Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
2000Hz
Set it the adjust-
ment value obtained
from the [Max Devi-
ation Adjust [Wide]
adjustment of step
6.
±50Hz
7. P25 high
deviation
*2
1) Adj item: [HDVA]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
Detector: ±PEAK/2
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[
✳✳✳
]
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [P25 High
Deviation]
Deviation
meter
LPF : 3kHz
HPF : OFF
Detector: ±PEAK/2
2) Adj item: [Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
2827Hz
Set it the ad-
justment value
obtained from the
[Max Deviation
Adjust [Narrow]
adjustment of step
6.
2771~2883Hz
*2: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 69.
Balance adjustment is common with the adjustment of all signaling deviation.