TK-5810
(
BG
)
/5810H
(
BG
)
72
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
(P25)
1) Adj item: [RRSIA]
Adjust:
[
✳✳✳
]
2) Adj item:
[L]
→
[C]
→
[H]
SSG
output
: –125dBm (0.126µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
1) Adj item: [RSSI
(Reference) (P25)]
2) Adj item: [Low]
→
[Center]
→
[High]
SSG
output
: –125dBm (0.126µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
SSG
AF VTVM
Oscillo-
scope
Rear
panel
ANT
Ext.SP
connector
[Panel
tuning
mode]
[PF5]
[PC test
mode]
[Apply]
[Panel tuning mode]
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
[PC test mode]
After input signal
from SSG, press
[Apply] key to store
the adjustment
value.
7. RSSI
(–120dBm)
(Wide)
1) Adj item: [LRSIW]
Adjust:
[
✳✳✳
]
2) Adj item:
[L]
→
[C]
→
[H]
SSG
output
: –120dBm (0.22µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
1) Adj item: [RSSI
(–120dBm) (Wide)]
2) Adj item: [Low]
→
[Center]
→
[High]
SSG
output
: –120dBm (0.22µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
(Narrow)
1) Adj item: [LRSIN]
Adjust:
[
✳✳✳
]
2) Adj item:
[L]
→
[C]
→
[H]
SSG
output
: –120dBm (0.22µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
1) Adj item: [RSSI
(–120dBm) (Narrow)]
2) Adj item: [Low]
→
[Center]
→
[High]
SSG
output
: –120dBm (0.22µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
(P25)
1) Adj item: [LRSIA]
Adjust:
[
✳✳✳
]
2) Adj item:
[L]
→
[C]
→
[H]
SSG
output
: –120dBm (0.22µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
1) Adj item: [RSSI
(–120dBm) (P25)]
2) Adj item: [Low]
→
[Center]
→
[High]
SSG
output
: –120dBm (0.22µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
8. RSSI
(–70dBm)
(Wide)
1) Adj item: [HRSIW]
Adjust:
[
✳✳✳
]
2) Adj item:
[L]
→
[C]
→
[H]
SSG
output
: –70dBm (70.7µV)
(MOD: OFF)
After input signal
from SSG, press
[PF5] key to store
the adjustment
value.
1) Adj item: [RSSI
(–70dBm) (Wide)]
2) Adj item: [Low]
→
[Center]
→
[High]
SSG
output
: –70dBm (70.7µV)
(MOD: OFF)
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.