48
If an error code is displayed, or odd behavior of the unit occurs, the fi rst corrective action should be to “Cycle the
Power”: Unplug the 120Vac power cord and after 5 seconds plug it in again. If this doesn’t clear the fault, proceed with
the “Remedy” in the following table (Table 4). The remedies for each fault code are put in logical order, so proceed one
by one, starting with #1.
If wire harness checking is required, examine the integrity of wires themselves, the connector housings, the integrity of
the terminals as well as condition of the crimps.
Fault
Code
Displayed
Description
Cause
Lockout
type
Remedy
E01, E02
Invalid Rated
KBtu/Model Type.
Control detects that the
confi guration selected is not
defi ned or the confi guration
has never been set.
Continuous Change the Control Board.
E03, E04,
E05, E06
Main Valve Relay
Out Of Sequence.
Control detects that a relay
used to enable the Main
Valve has failed in either the
open or closed position.
Soft
Change the Control Board.
E07
Flame Detected.
Flame detected when no
fl ame was expected.
Soft
Check the Flame Sensor.
Check the fl ame wire harness.
Change the Control Board.
1.
2.
3.
E08
ECO Switch is
open.
Control detects that the
ECO Switch is open,
preventing power to the
Main Valve.
Continuous
Check inlet water fi lter.
Measure the water temperature.
ECO Switch open temperature
is 85±5ºC (185±14ºF) and close
temperature is 65±5ºC (149±14ºF).
Check the ECO Switch.
Check the ECO wire harness.
Change the Control Board.
1.
2.
3.
4.
5.
E09
High Temperature
Switch open.
Control detects that the High
Temperature Switch is open,
preventing power to the
Main Valve.
Continuous
Measure the exhaust gas
temperature. High Temperature
Switch open temperature is
74±2.8ºC (165±5ºF) and close
temperature is 57±2.8ºC (135±5ºF).
Check the switch.
Check the High Temperature Switch
wire harness.
Change the Control Board.
1.
2.
3.
4.
E10
120Vac too high.
120Vac > Overvoltage Limit.
Auto Reset
Nominal voltage is 120Vac.
Overvoltage limit is 132Vac,
Undervoltage limit is 102Vac.
Check the power cord.
Check the wall outlet.
Measure the voltage at the board
connector J7 between pin1 and pin
3. If the voltage is between limits,
change the Control Board.
1.
2.
3.
E11
120Vac too low.
120Vac < Undervoltage
Limit.
TABLE 4