GENERAL SAFETY
Breathing carbon monoxide can cause brain damage or death.
Always read and understand instruction manual.
• Install vent system In accordance with codes.
• Do not operate water heater if flood damaged.
• Standard model is fitted for operation at altitudes
up to 3,500 ft. (1,067m). High Altitude model is
suitable for altitudes between 3,501 to 6,500 ft.
(1,067m and 1,981m). Specific accessory kits are
required for installations above 6,500 ft. (1,981m).
• Do not operate if soot buildup is present.
• Do not obstruct water heater air intake with
insulating jacket.
• Do not place chemical vapor emitting products
near water heater.
• Gas and carbon monoxide detectors are
available.
• No vent damper installation is compatible with
this power vented water heater.
• Do not elevate the condensate hose on the
bottom of the water heater above the bracket
attached to the side of the unit. This must be true
for the entire length of the hose including the exit
into an appropriate drain.
• Condensate lines must be free and clear of debris
and must not allow back flow through the hose.
The condensate lines must be able to flow freely
to an appropriate drain.
• Do not allow condensate lines to become crimped
closed.
• Analyze the entire vent system to make sure that
condensate will not become trapped in a section
of vent pipe and therefore reduce the open cross
sectional area of the vent.
Breathing Hazard - Carbon Monoxide Gas
WARNING
Installation: Do not install the water heater where flammable
products will be stored or used. It must be installed a minimum
of 18 in. (45cm) above the floor if installed in a residential
garage. This will reduce, but not eliminate, the risk of flammable
vapors being ignited by the main burner or spark igniter.
Vapors from flammable
liquids may explode and
catch fire causing death or
severe burns.
Do not use or store
flammable products such as
gasoline, solvents or adhe-
sives in the same room or
area near the water heater.
Keep flammable products:
1. far away from heater,
2. in approved containers,
3. tightly closed and
4. out of children's reach.
Water heater has a main
burner and spark generator.
The spark generator:
1. can be triggered at any
time and
2. the spark will ignite
flammable vapors.
Vapors:
1. cannot be seen,
2. are heavier than air,
3. go a long way on the floor
and
4. can be carried from other
rooms to the the
electodes by air currents.
Flammable Vapors
FLAMMBLE
DANGER
• Before servicing the water heater, make
sure the water heater is unplugged from
the electrical supply.
• Label all wires prior to disconnection
when servicing controls. Wiring error can
cause improper and dangerous opera-
tion. Verify proper operation after
servicing.
• Failure to do this could result in death,
serious bodily injury, or property
damage.