1. SPECIFICATIONS
1-1 DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips,
nuts or washers used to complete a path to ground are removed for service, they must be returned to their original position
and properly fastened.
This information is intended for use by individuals possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible for the interpretation of this information, not can it assume any
liability in connection with its use.
1-2 IMPORTANT NOTICE
Temperature Control (Position: MID)........................................................................................................................-6°F to +8°F
Defrost Control.............................................................................................................................................................Automatic
Defrost Thermostat...............................................................................................................................................................50°F
Electrical Rating: 115VAC, 60Hz..........................................................................................................................................1-7 A
Maximum Current Leakage................................................................................................................................................0.5mA
Maximum Ground Path Resistance..............................................................................................................................0.1 Ohms
Energy Consumption...............................................................................................................27 cu.ft. 590kWh/yr (Energy Star)
And ambient of:...........................................................................70°F ...............................................................................90°F
Fresh Food, °F................................................................33°F to 41°F ..................................................................33°F to 41°F
Frozen Food, °F...............................................................-4°F to +4°F ......................................................................45%-60%
Percent Running Time.....
Minimum Compressor Capacity Vacuum..............................21 in
Minimum Equalized Pressure
@ 70°F ............................................................49PSIG
@ 90°F ............................................................56PSIG
Refrigerant R134a...............................................................6.5 oz
Compressor.................................................................950BTU/hr
For proper air circulation, best cooling and energy
consumption results, maintain a minimum distance of 2
inches (5.08cm) from adjacent items and surfaces.
CLEARANCE
AT TOP...........................................................................2 in
AT SIDES.......................................................................2 in
AT REAR........................................................................2 in
1-3 ELECTRICAL SPECIFICATIONS
1-4 NO LOAD PERFORMANCE
Control Position: MID/MID
1-5 REFRIGERATION SYSTEM
1-6 INSTALLATION
1-7 REFRIGERATION SYSTEM
- 4 -
Содержание 795.58822.900
Страница 16: ... 16 CON1 CON2 CON3 CON4 CON5 CON6 CON7 CON8 CON10 CON9 ...
Страница 72: ... 72 19 7 13 12 4 1 2 3 22 18 10 15 9 8 17 14 16 ...
Страница 73: ... 73 5 WATER VALVE DISASSEMBLY METHOD ...
Страница 75: ...REFRIGERATOR DOOR EXPLODED VIEW 241H 233A 231A 241D 243B 230A 212G 241B 241C 241A 241H 241H 212J 75 EV 244A ...
Страница 84: ...April 2009 ...