2. ICEMAKER FUNCTIONS
2-1. Start Position
1. After POWER OFF or power outage, check the EJECTOR's position with MICOM initialization to restart.
2. How to check if it is in place:
- Check
HIGH/LOW
signals from HALL SENSOR in MICOM PIN.
3. Control Method to check if it is in place:
(1) EJECTOR is in place,
- It is an initialized control, so the mode can be changed to icemaking mode.
(2) EJECTOR isn't in place:
A. If EJECTOR is back in place within 2 minutes with the motor on, it is being initialized. If not, go to Step B.
B. Control the heater using the temperature sensor until the EJECTOR reaches the correct location.
2-2. Icemaking Mode
1. Icemaking refers to the freezing of supplied water in the ice tray. Complete freezing is assured by measuring the
temperature of the Tray with Icemaking SENSOR.
2. Icemaking starts after completion of the water fill operation.
3. The Ice Making function is completed when the sensor reaches 19
°
F (-7
°
C), 55 minutes after starting.
4. If the temperature sensor is defective, the ice-making function will be completed in 4 hours.
NOTE :
After Icemaker Power is ON, the Icemaker heater will be on for test for 6 sec.
2-3. Harvest Mode
1. Harvest (Ice removing) refers to the operation of dropping ices into the ice bin from the tray when icemaking has
completed.
2. Harvest mode:
(1) The Heater is ON for 30 seconds, then the motor starts.
(2) The feeler arm senses the quantity of ice in the ice storage bin while rotating with the EJECTOR.
A. Ice storage bin is full : The EJECTOR stops (heater off).
B. Ice storage bin is not full : The EJECTOR rotates twice to open for ice.
If the EJECTOR does not rotate once within 5 minutes in B mode, separate heater control mode starts operating to
prevent the EJECTOR from being constrained. (It is recommended that the user open for ice to return to normal mode.)
2. The amount of water is adjusted by pressing the Fill Key repeatedly. This changes the time allowed for fill as illustrated in
the table below.
Water supply amount TABLE
STAGE
TIME TO SUPPLY
INDICATIONS
REMARKS
1
2
3
5 sec.
5.5 sec.
(FIRST STAGE)
6 sec.
The water amount will vary depending
on the water control switch setting, as
well as the water pressure of the
connected water line.
- 29 -
2-4. Fill/Park position
1. Once a normal harvest mode has been completed, the water solenoid will be activated.
Содержание 795.58822.900
Страница 16: ... 16 CON1 CON2 CON3 CON4 CON5 CON6 CON7 CON8 CON10 CON9 ...
Страница 72: ... 72 19 7 13 12 4 1 2 3 22 18 10 15 9 8 17 14 16 ...
Страница 73: ... 73 5 WATER VALVE DISASSEMBLY METHOD ...
Страница 75: ...REFRIGERATOR DOOR EXPLODED VIEW 241H 233A 231A 241D 243B 230A 212G 241B 241C 241A 241H 241H 212J 75 EV 244A ...
Страница 84: ...April 2009 ...