- 19 -
EVA-FAN
CONDENSER-FAN
CONNECTOR 7
F-DOOR S/W
2*RD
PIN 5&6
CON7 (PIN5&6)
CONNECTOR 9
R-DOOR S/W
BO, PK
PIN 3&4
CON9 (PIN4&3)
• Since door switches (A) and (B) are interconnected, if either fails, the other will not respond properly.
• If either switch fails, the light will not come on.
Closing
5 V ( A - B , C - D . Switch at both ends are at Off status)
Opening
0 V ( A - B , C - D . Switch at both ends are at On status)
Measuring part
Door of Freezer / Refrigerator
IC1 (MICOM) PIN 39, 40