![Kenmore 795.58822.900 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/kenmore/795-58822-900/795-58822-900_service-manual_1954947035.webp)
CLAIMS.
CAUSES AND CHECK POINTS.
HOW TO CHECK
3. Refrigeration
is weak.
4) No cooling air circulation.
5) Compressor capacity.
6) Refrigerant
too much or too little.
7) Continuous operation
- No contact of temperature controller. - Foreign materials.
8) Damper opens continuously.
Foreign materials
jammed.
Failed sensor. - Position of sensor.
Characteristics
of damper.
9) Food storing place. - Near the outlet of cooling air.
Faulty fan motor.
Small cooling air
discharge.
Fan is
constrained.
Insufficient
motor RPM
Faulty fan.
Shorud. Bent.
Ice and foreign materials on rotating parts.
Fan shroud contact. - Clearance.
Damping evaporator contact.
Accumulated residual frost.
Fan misuse.
Bad shape.
Loose connection. - Not tightly connected.
Insert depth.
Rating misuse.
Small capacity.
Low valtage.
Malfunction of charging cylinder.
Wrong setting of refrigerant.
Insufficient compressor. - Faulty compressor.
Fan overload. - Fan misuse.
Bad low termperature RPM characteristics.
Rated power misuse.
Low voltage.
Adiabatics liquid dump.
The EPS (styrofoam) drip tray has sediment in it.
A screw or other foreign material has fallen into the drip
tray or damper.
Bad characteristics of its own temperatue.
Parts misuse.
Charge of temperature - Impact.
characteristics.
• Check visually after
disassembly.
• Check visually after
disassembly.
- 35 -
Содержание 795.58822.900
Страница 16: ... 16 CON1 CON2 CON3 CON4 CON5 CON6 CON7 CON8 CON10 CON9 ...
Страница 72: ... 72 19 7 13 12 4 1 2 3 22 18 10 15 9 8 17 14 16 ...
Страница 73: ... 73 5 WATER VALVE DISASSEMBLY METHOD ...
Страница 75: ...REFRIGERATOR DOOR EXPLODED VIEW 241H 233A 231A 241D 243B 230A 212G 241B 241C 241A 241H 241H 212J 75 EV 244A ...
Страница 84: ...April 2009 ...