Kendrion Binder Magnete GmbH
Operating Instructions 76 ..P..B00
Last updated: 30 Dec. 2009
Page 13
Size
10
11
13
16
19
24
M
A
tightening torque [Nm] of machine screws (20) for
cover (7)
5.6
5.6
24
24
45
45
M
A
tightening torque [Nm] of machine screws (22) for
flange (3)
7.6
7.6
9.7
9.7
24
24
M
A
tightening torque [Nm] of machine screws (27) for
cover (26) of connector box (25)
3
3
3
3
3
3
Table 13/1: Tightening torques of machine screws
Note!
Machinery-specific regulations and requirements (e.g. for hoists, cranes and elevators) must be observed
when using brakes with microswitches (13).
Warning!
The motor circuit must be protected in such a way that no accidental motor start-up can occur when the
microswitch (13) contact closes.
Note!
The suggested wiring of the spring-applied single-disc brake with microswitch (13) shown in Fig. 11/1 is
based on the generally accepted recommendations for the connection of electromagnetic components used
in electric machinery (e.g. motors) without load torque impact. When the brake is used for applications during
which a load torque is generated, the system user is responsible to ensure correct and safe wiring of the
microswitch (13) and spring-applied single-disc brake.