17
Robot Gun Mount T1
© Kemppi Oy 2016
1616
OPERA
TING M
ANU
AL
14.1 Cleaning robot mount T1 with A7
MIG Gun 500-g
This section describes how to clean robot mount T1 with
A7 MIG Gun 500-g.
Figure 12: Cleaning robot mount T1 with A7 MIG Gun 500-g
1. Bellows
2. Cover ring
3. O-ring, 28×1.5
4. 2 set screws
5. Robot mount T1
6. Screw
7. Washer
8. Fastening screw
9. Threaded sleeve
Risk of injury
Serious injuries can be caused by parts articulating rapidly.
When cleaning with compressed air, wear suitable
protective clothing – in particular, safety goggles.
Proceed as follows:
1. Clean (5) with compressed air.
2. Unscrew the threaded sleeve (9), and pull it off,
together with the bellows (1).
3. Turn the cover ring (2) to the right as far as it will
go, and remove it.
4. Check the O-ring (3) for wear, and replace it if
necessary.
5. Clean the bores of the set screws (4) with
compressed air.
6. Check the set screws (4) for wear, and replace them
if necessary.
7. Grease the O-ring (3) with sealing grease (included
in the delivery).
8. Remove the screw (6), washer (7), and fastening
screw (8), and clean them, as a single assembly,
with compressed air.
9. Blow compressed air through the bores.
10. Attach the fastening screw (8) and washer (7), and
then remove the screw labeled “6” again.
11. Mount the set screws (4), O-ring (3), cover ring (2),
and threaded sleeves (9, then 1).
Содержание Robot Gun Mount T1
Страница 1: ...T1 1920630 1616 Robot Gun Mount EN OPERATING MANUAL...
Страница 23: ...And you know...