50
SPN 65560
SPN Descriptors
SPN 65560 FMI 9:
CAN Bus Governor Command Abnormal Update Rate
SPN 65561, 65562, 65563, or 65564
SPN Descriptors
SPN 65561 FMI 0:
Oxygen Sensor Bank A Sensor 1 Data Valid But Above Normal
SPN 65561 FMI 1:
Oxygen Sensor Bank A Sensor 1 Data Valid But Below Normal
SPN 65561 FMI 3:
Oxygen Sensor Bank A Sensor 1 Voltage Above Normal or Shorted High
SPN 65561 FMI 4:
Oxygen Sensor Bank A Sensor 1 Voltage Below Normal or Shorted Low
SPN 65561 FMI 5:
Oxygen Sensor Bank A Sensor 1 Current Below Normal or Open Circuit
SPN 65562 FMI 0:
Oxygen Sensor Bank A Sensor 2 Data Valid But Above Normal
SPN 65562 FMI 1:
Oxygen Sensor Bank A Sensor 2 Data Valid But Below Normal
SPN 65562 FMI 3:
Oxygen Sensor Bank A Sensor 2 Voltage Above Normal or Shorted High
SPN 65562 FMI 4:
Oxygen Sensor Bank A Sensor 2 Voltage Below Normal or Shorted Low
SPN 65562 FMI 5:
Oxygen Sensor Bank A Sensor 2 Current Below Normal or Open Circuit
SPN 65563 FMI 0:
Oxygen Sensor Bank B Sensor 1 Data Valid But Above Normal
SPN 65563 FMI 1:
Oxygen Sensor Bank B Sensor 1 Data Valid But Below Normal
SPN 65563 FMI 3:
Oxygen Sensor Bank B Sensor 1 Voltage Above Normal or Shorted High
SPN 65563 FMI 4:
Oxygen Sensor Bank B Sensor 1 Voltage Below Normal or Shorted Low
SPN 65563 FMI 5:
Oxygen Sensor Bank B Sensor 1 Current Below Normal or Open Circuit
SPN 65564 FMI 0:
Oxygen Sensor Bank B Sensor 2 Data Valid But Above Normal
SPN 65564 FMI 1:
Oxygen Sensor Bank B Sensor 2 Data Valid But Below Normal
SPN 65564 FMI 3:
Oxygen Sensor Bank 2 Sensor 2 Voltage Above Normal or Shorted High
SPN 65564 FMI 4:
Oxygen Sensor Bank B Sensor 2 Voltage Below Normal or Shorted Low
SPN 65564 FMI 5:
Oxygen Sensor Bank B Sensor 2 Current Below Normal or Open Circuit
SPN 65565 or 65566
SPN Descriptors
SPN 65565 FMI 0:
Fuel Trim Bank 1 Data Valid But Above Normal
SPN 65565 FMI 1:
Fuel Trim Bank 1 Data Valid But Below Normal
SPN 65566 FMI 0:
Fuel Trim Bank 2 Data Valid But Above Normal
SPN 65566 FMI 1:
Fuel Trim Bank 2 Data Valid But Below Normal
SPN 65567 or 65568
SPN Descriptors
SPN 65567 FMI 8:
Oxygen Sensor Bank 1 Sensor 1 Abnormal Frequency or Pulse Width
SPN 65567 FMI 10:
Oxygen Sensor Bank 1 Sensor 1 Abnormal Rate of Change
SPN 65568 FMI 8:
Oxygen Sensor Bank 2 Sensor 1 Abnormal Frequency or Pulse Width
SPN 65568 FMI 10:
Oxygen Sensor Bank 2 Sensor 1 Abnormal Rate of Change
SPN 65570
SPN Descriptors
SPN 65570 FMI 2:
Cam Phaser W Data Erratic, Intermittent, or Incorrect
SPN 65570 FMI 4:
Cam Phaser W Voltage Below Normal or Shorted Low
SPN 65570 FMI 5:
Cam Phaser W Short High or Open
SPN 65570 FMI 7:
Cam Phaser W Accuracy Mechanical System Not Responding or Out of
Adjustment