K°Bloc – Fully welded plate heat exchangers - English Version 2.2 - 01.2016
90
7.4.2.3
TIGHTENING THE PANEL - TO A GAP DIMENSION
The gap is measured between the panels and the columns and end
bottom/top heads.
Requirement:
Take the permitted gap size from the technical documentation or the
name plate.
Carry out the following steps:
1.
Tighten all nuts of panel "I" crosswise to a 5 mm gap according to the
figure below (here: 1 to 22).
Figure 7.4.2.3.a
Panel with
corner bolt hole
Panel without
corner bolt hole