 refrigerant pipe connection/electrical work  15

14  refrigerant pipe connection  

Kelvinator Air Conditioning

Connect the cable to the indoor unit

•   Connect the cable to the indoor unit by connecting the 

wires to the terminals on the control box individually 
according to the outdoor unit connection.

 

 (Ensure that the colour of the wires of the outdoor unit 
and the terminal number are the same as those of the 
indoor unit.

1.   Remove the electrical box cover from the outdoor unit 

by loosening the screw.

2.   Connect wires from the Indoor Unit to the terminals on 

the  Outdoor Unit as identified by their colours.

3.   Secure the cable onto the control board with the 

cord clamp.

4.   Be sure to install the power supply for all models 

according to the diagram below. Be sure to firmly 
connect the Earthing wire.

5.   To waterproof, make a wire loop as detailed in the 

Installation Diagram of Indoor and Outdoor Units.

6.   Wrap wires (conductors) that were not connected with 

insulating tape so that they do not touch any electrical 
or metal parts.

Note:  

•    

Wrong wire connection may cause some electrical parts 
to malfunction.

•   

The supply voltage must be consistent with the rate 
voltage of the air conditioner.

Connect the cable to the indoor unit

Note:  Before performing any electrical work, turn off the main 

power to the system.

Electrical Work

B:   Finally, tighten the flare nut with torque wrench until 

the wrench clicks.

•    Tighten the flare nut with a wrench, in accordance with 

the following table.

Outer 

Diameter.

Tightening torque 

(Kg.m)

Additional Tightening 

Torque (Kg.m)

1/4” (6.35mm)

1.6

2.0

3/8” (9.53mm)

3.0

3.5

1/2” (12.7mm)

5.0

5.5

5/8” (16.0mm)

7.5

8.0

H:   Set the piping and the drain hose to the back of the 

chassis with the tubing holder.

•   Set the tubing retainer into position and tighten screw.

Tubing retainer

I:   Reroute the piping and the drain hose across the back 

of the chassis, for rear left side external passage.

J:  Locating the indoor unit

•  Remove the spacer.
•   Hook the indoor unit onto the upper portion of 

the installation plate (Engage the hooks of the 
installation plate into the openings at the rear top 
of the indoor unit.) 
Ensure that the hooks are properly seated on the 
installation plate by moving the indoor unit left 
and right.

•   Press the lower left and right sides of the unit against the 

installation plate until the hooks engage into their slots 
(clicking sound).

Connecting

cable

Connection of Pipes – Outdoor

A:   Align the centre of the piping and sufficiently tighten 

the flare nut by hand.

D:   Insert the piping, drain hose and the connecting cable 

into the piping hole.

E:  Indoor unit installation

•   Hang the indoor unit from the hooks at the top of the 

installation plate.

•   Insert a spacer between the indoor unit and the 

installation plate to separate the bottom of the unit from 
the wall.

F:   Connecting the piping to the indoor unit and the drain 

hose to drain pipe.

•   Align the centre of the piping and sufficiently tighten the 

flare nut by hand.

•   Tighten the flare nut with a wrench, in accordance with 

the following table.

Outer 

Diameter.

Tightening torque 

(Kg.m)

Additional Tightening 

Torque (Kg.m)

1/4” (6.35mm)

1.6

2.0

3/8” (9.53mm)

3.0

3.5

1/2” (12.7mm)

5.0

5.5

5/8” (16.0mm)

7.5

8.0

 

•  When extending the drain hose of the indoor unit, 

install the drain pipe extension as shown in the 
diagram below.

G:   Wrap the insulation material around the piping 

connections

•   Overlap the connection piping heat insulation and the 

indoor unit pipe heat insulation material. Bind them 
together with vinyl tape so that there is no gap.

Terminal block of indoor unit

 model(26 00k w)

 model(53 00k w)

 model(70 00k w)

 model(80 00k w)

E lectrical box

cover

Fro nt P ane l

10mm

40mm

Code wire

 model(35 00k w)

 model(62 00k w)

Co rd c lamp

To outdoor unit

To outdoor unit

   S

 2(N)

S  

L

L( 1)

To outdoor unit

Cor d clamp

L    N   

 S   

Содержание KSV26HRB

Страница 1: ...Inverter Split type Room Air Conditioner Installation Manual KSV26HRB KSV35HRB KSV53HRB KSV62HRB KSV70HRB KSV80HRB Refrigerant R410A ...

Страница 2: ...g the appliance tips and information This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance This symbol indicates never to do this This symbol indicates always do this Important safety instructions 2 Contents Kelvinator Air Conditioning Congratulations and thank you for ...

Страница 3: ...fied torque wrenches 1 8kgf m 4 2kgf m 5 5kgf m 6 6kgf m different depending on model No Spanner half union Hexagonal wrench 4mm Gas leak detector Vacuum pump Gauge manifold Users manual Thermometer Multimeter Pipe cutter Measuring tape Items required for installing the unit Number Name of Accessories Qty 1 Installation Plate 1 2 Clip Anchor 8 3 Self tapping Screw A 8 4 Seal See page 8 for details...

Страница 4: ... unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the space on the left and right of the unit is more than 12cm Use a stud finder to locate studs to prevent unnecessary damage to the wall The indoor unit should be installed on the wall at a height of 2 0m or more from the floor The indoor unit should be installed allowing a minimum...

Страница 5: ... pipe hole 65 Left rear side refrigerant pipe hole 65 12cm or more to wall 12cm or more to wall 850 45 90 45 45 272 80 489 6 2kw model 12cm or more to the wall to the wall 12cm or more 50 15cm or more to the ceiling Indoor Unit Outline 380 Hooked Part 380 998 322 119 130 65 65 130 50 Above 12cm to the wall Above 12cm to the wall Above 15cm to the ceiling 325 55 95 95 55 1250 815 257 178 55 58 Pipe...

Страница 6: ...ing of outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount Model A mm B mm 3 5kw 530 290 5 3kw 560 335 6 2kw 590 333 A B Air inlet Air outlet Air inlet Drain joint installation If a drain elbow is used the unit should be placed on a stand which is taller than 3cm If the unit is used in an area where temperature falls below 0O C for...

Страница 7: ...ing section C Tape the tubing drain hose and the connecting cable Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Note If the drain hose is routed inside the room insulate the hose with insulation material so that dripping from sweating condensation will not damage furniture or floors Foamed polyethy...

Страница 8: ...n screw Tubing retainer I Reroute the piping and the drain hose across the back of the chassis for rear left side external passage J Locating the indoor unit Remove the spacer Hook the indoor unit onto the upper portion of the installation plate Engage the hooks of the installation plate into the openings at the rear top of the indoor unit Ensure that the hooks are properly seated on the installat...

Страница 9: ...rcuit diagram posted on the inside of the control cover 2 The screws which fasten the wiring in the casing of electrical fittings may come loose from vibrations to which the unit is subjected during the course of transportation Check them and make sure that they are all tightly fastened If they are loose it could cause burn out of the wires 3 Specification of power source 4 Confirm that electrical...

Страница 10: ...an the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Manifold valve Compound meter 76cmHg Handle L o Handle Hi Charge hose Charge hose Vacuum pump Pressure gauge Low pressure valve Air purging Air purging Air and moisture in the refrigerant system have undesirable effects as ...

Страница 11: ...AUTO or COOL mode see User Manual for details The test operation should last about 30 minutes Manual control button AUTO COOL Rated Capacity Test Cooling mode Under Cooling Mode set the air conditioner at High Fan Speed and set the temperature to 17O C then press the TURBO button 6 times within 10 seconds be sure the indoor unit buzzes 6 times The system will enter Rated Capacity Test mode The buz...

Страница 12: ...rchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and t...

Страница 13: ...rmation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: