warning

 

Do not install yourself.

Incorrect installation could cause injury due to fire, 
electrical shock, the unit falling or leakage of water. 
Consult the dealer from whom you purchased the 
unit or authorised installer.

Perform the installation securely referring to the 
installation instruction.

Incorrect installation could cause a personal injury 
due to fire, electric shock, the unit falling or leakage 
of water.

Install the unit securely in a place which can bear the 
weight of the unit.

If installed in a structurally unsound location, the unit 
could fall causing injury.

 

Perform electrical work according to the installation 
manual and be sure to use a dedicated circuit.

If the capacity of the power circuit is insufficient or 
there is incomplete electrical work, it could result in a 
fire or an electric shock.

 

Use the specified wires to connect the indoor and 
outdoor units. Securely attach the wires to the 
terminal board connecting sections so the stress of 
the wire is not applied to the sections.

Incorrect connection and fixing could cause a fire.

Check that the refrigerant gas does not leak after 
installation is complete.

Leak refrigerant could be a hazard to health and the 
environment.
Unit may not perform to full capacity and life of unit 
may reduce.

Be sure to use the parts provided or specified parts 
for the installation work.

The use of defective parts could cause an injury due 
to a fire, electric shock, the unit falling etc.

Perform the drainage/piping work according to the 
installation instruction.

If there is a defect in the drainage/piping work, water 
could leak from the unit and household goods could 
get wet or be damaged

Operating temperature

Cooling Mode

Indoor

Outdoor

Max.

Min.

Max.

Min.

32°C

17°C

50°C

18°C

Heating Mode

Indoor

Outdoor

Max.

Min.

Max.

Min.

27°C

17°C

34°C

-15°C

Note:  Optimum performance will be achieved within these 

operating temperatures.

Please read the user manual before installation and carefully 
store in a handy place for later reference. Inside you will 
find many helpful hints on how to install and test the air 
conditioner properly. 
Electrical work must be performed by a licensed electrician. 
Be sure to use the correct rating of the power plug and main 
circuit for the model to be installed.
Incorrect installation due to ignoring of the instruction will 
cause harm or damage, and the seriousness is classified by 
the following indications.
Meanings of symbols used in this manual are shown below:

warning

This symbol indicates information concerning your  
personal safety

caution

This symbol indicates information on how to avoid 
damaging the appliance

tips and information

This symbol indicates tips and information about  
use of the appliance

environmental tip 

This symbol indicates tips and information about 
economical and ecological use of the appliance

 

This symbol indicates never to do this

 

This symbol indicates always do this

Important safety instructions

2  Contents  

Kelvinator Air Conditioning

Congratulations and thank you for choosing our Inverter 
split-type room air conditioner. We are sure you will find  
your new air conditioner a pleasure to use. Before you use 
the air conditioner, we recommend that you read through  
the entire user manual, which provides the description of  
the air conditioner and its functions.
To avoid the risks that are always present when you use an 
electrical appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not 
damaged. If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

environmental tip 

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this air conditioner, please contact 

your local authorities and ask for the correct method  
of disposal.

caution

•    The air conditioner is not intended for use by young 

children or infirmed persons without supervision.

•    Young children should be supervised to ensure that they 

do not play with the air conditioner. 

•    Contact an authorised installer for installation of this unit.
•    Contact an authorised service technician for repair or 

maintenance of this unit.

•    If the power cord is to be replaced, replacement work  

shall be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with the national wiring Standards by authorised 
personnel only.

Conditions of use

This appliance is intended to be useed in household and 
similar applications such as:

•    

Staff kitchen areas in shops, offices and other working 
environments

•  

Farm houses

•    

By clients in hotels, motels, and other residential 
type environments

•  

Bed and breakfast type environments

Safety instructions

Warning .........................................................................................3
Caution ..........................................................................................3

Installation instructions

Select the right place for installation .........................................6
Indoor unit installation ................................................................9
Outdoor unit installation ...........................................................10

Refrigerant pipe connection   ...........................................10

Electrical work .................................................................15

Air purging

Air purging with vacuum pump ................................................18
Safety and leakage check .........................................................19

Test running.....................................................................19

Congratulations

Contents

Kelvinator Air Conditioning

  Important safety instructions  3

Содержание KSV26HRB

Страница 1: ...Inverter Split type Room Air Conditioner Installation Manual KSV26HRB KSV35HRB KSV53HRB KSV62HRB KSV70HRB KSV80HRB Refrigerant R410A ...

Страница 2: ...g the appliance tips and information This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance This symbol indicates never to do this This symbol indicates always do this Important safety instructions 2 Contents Kelvinator Air Conditioning Congratulations and thank you for ...

Страница 3: ...fied torque wrenches 1 8kgf m 4 2kgf m 5 5kgf m 6 6kgf m different depending on model No Spanner half union Hexagonal wrench 4mm Gas leak detector Vacuum pump Gauge manifold Users manual Thermometer Multimeter Pipe cutter Measuring tape Items required for installing the unit Number Name of Accessories Qty 1 Installation Plate 1 2 Clip Anchor 8 3 Self tapping Screw A 8 4 Seal See page 8 for details...

Страница 4: ... unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the space on the left and right of the unit is more than 12cm Use a stud finder to locate studs to prevent unnecessary damage to the wall The indoor unit should be installed on the wall at a height of 2 0m or more from the floor The indoor unit should be installed allowing a minimum...

Страница 5: ... pipe hole 65 Left rear side refrigerant pipe hole 65 12cm or more to wall 12cm or more to wall 850 45 90 45 45 272 80 489 6 2kw model 12cm or more to the wall to the wall 12cm or more 50 15cm or more to the ceiling Indoor Unit Outline 380 Hooked Part 380 998 322 119 130 65 65 130 50 Above 12cm to the wall Above 12cm to the wall Above 15cm to the ceiling 325 55 95 95 55 1250 815 257 178 55 58 Pipe...

Страница 6: ...ing of outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount Model A mm B mm 3 5kw 530 290 5 3kw 560 335 6 2kw 590 333 A B Air inlet Air outlet Air inlet Drain joint installation If a drain elbow is used the unit should be placed on a stand which is taller than 3cm If the unit is used in an area where temperature falls below 0O C for...

Страница 7: ...ing section C Tape the tubing drain hose and the connecting cable Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Note If the drain hose is routed inside the room insulate the hose with insulation material so that dripping from sweating condensation will not damage furniture or floors Foamed polyethy...

Страница 8: ...n screw Tubing retainer I Reroute the piping and the drain hose across the back of the chassis for rear left side external passage J Locating the indoor unit Remove the spacer Hook the indoor unit onto the upper portion of the installation plate Engage the hooks of the installation plate into the openings at the rear top of the indoor unit Ensure that the hooks are properly seated on the installat...

Страница 9: ...rcuit diagram posted on the inside of the control cover 2 The screws which fasten the wiring in the casing of electrical fittings may come loose from vibrations to which the unit is subjected during the course of transportation Check them and make sure that they are all tightly fastened If they are loose it could cause burn out of the wires 3 Specification of power source 4 Confirm that electrical...

Страница 10: ...an the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Manifold valve Compound meter 76cmHg Handle L o Handle Hi Charge hose Charge hose Vacuum pump Pressure gauge Low pressure valve Air purging Air purging Air and moisture in the refrigerant system have undesirable effects as ...

Страница 11: ...AUTO or COOL mode see User Manual for details The test operation should last about 30 minutes Manual control button AUTO COOL Rated Capacity Test Cooling mode Under Cooling Mode set the air conditioner at High Fan Speed and set the temperature to 17O C then press the TURBO button 6 times within 10 seconds be sure the indoor unit buzzes 6 times The system will enter Rated Capacity Test mode The buz...

Страница 12: ...rchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and t...

Страница 13: ...rmation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...