Kelvinator KSV26HRB Скачать руководство пользователя страница 3

Kelvinator Air Conditioning 

 typical installation  5

4  before installation  

Kelvinator Air Conditioning

caution

•    Use a stud finder to locate studs to prevent 

unnecessary damage to the wall.

•    A minimum pipe run of 3 metres is required to 

minimise vibration & excessive noise.

•    Two of the A, B and C directions should be free 

from obstructions.

•    This illustration is for explanation purposes only.
•   Copper lines must be insulated independently.

KSV

26

H

R

B

KSV

26

H

R

C

K

SV3

5H

RB

KSV

35

H

R

C

KSV

53

H

R

C

K

SV

62

HR

C

KSV

70H

R

B

KSV

70H

R

C

KSV

80H

R

C

InDOOR

Remote control 
(Including Holder)

1

1

1

Battery

2

2

2

Tubing plug

1

1

1

Self-tapping  Screw 
ST4.2*25 TA

5

10

10

Manual

1

1

1

OUTDOOR

Drainage plug

-

3

3

Drainage Joint and seal

1

1

1

Before Installation

Typical installation  

(shows minimum clearances required for effective operation and access 
for service and maintenance)

Tools needed for installation

Level gauge
Screwdriver
Electric drill, Hole core drill ( 65mm)
Flaring tool set
Specified torque wrenches: 1.8kgf.m,
4.2kgf.m, 5.5kgf.m, 6.6kgf.m
(different depending on model No.)
Spanner (half union)
Hexagonal wrench (4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape

Items required for installing the unit

number Name of Accessories

Qty

Installation Plate

1

2

Clip Anchor

8

3

Self-tapping Screw A

8

4

Seal (See page 8 for details)

1

5

Drain Joint (See page 8 for details)

1

6

Connecting
pipe Assembly

Liquid 
Side

φ

6.35

Parts 
you must 
purchase

(A minimum
pipe wall-
thickness
of 0.7mm 
is required.)

φ

9.52

(<3.5kW model)

Gas 
Side

φ

12.70

(>=3.5kW model)

7

Remote control

1

Note:  Excluding the parts that are provided with the unit 

detailed above all other parts must be purchased 
separately.

Pipes needed for installation (Purchase separately according 
the following table).

Diameter

2.6kW

3.5kW&5.3kW

>=6.2kW

6.35mm 

Yes

Yes

No

9.35mm

Yes

No

Yes

12.7mm

No

Yes

No

16.0mm

No

No

Yes

Yes: Pipe needed on model.   No: Pipe not needed on model.

Loop the

connective

cable.

Air Outlet

15cm clearance

2

1

3

6

7

2.0m below 

60cm above

Air Filter

30cm left

12cm right

30cm behind

60cm right 

2.0m front

A

B

C

12cm left

Содержание KSV26HRB

Страница 1: ...Inverter Split type Room Air Conditioner Installation Manual KSV26HRB KSV35HRB KSV53HRB KSV62HRB KSV70HRB KSV80HRB Refrigerant R410A ...

Страница 2: ...g the appliance tips and information This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance This symbol indicates never to do this This symbol indicates always do this Important safety instructions 2 Contents Kelvinator Air Conditioning Congratulations and thank you for ...

Страница 3: ...fied torque wrenches 1 8kgf m 4 2kgf m 5 5kgf m 6 6kgf m different depending on model No Spanner half union Hexagonal wrench 4mm Gas leak detector Vacuum pump Gauge manifold Users manual Thermometer Multimeter Pipe cutter Measuring tape Items required for installing the unit Number Name of Accessories Qty 1 Installation Plate 1 2 Clip Anchor 8 3 Self tapping Screw A 8 4 Seal See page 8 for details...

Страница 4: ... unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the space on the left and right of the unit is more than 12cm Use a stud finder to locate studs to prevent unnecessary damage to the wall The indoor unit should be installed on the wall at a height of 2 0m or more from the floor The indoor unit should be installed allowing a minimum...

Страница 5: ... pipe hole 65 Left rear side refrigerant pipe hole 65 12cm or more to wall 12cm or more to wall 850 45 90 45 45 272 80 489 6 2kw model 12cm or more to the wall to the wall 12cm or more 50 15cm or more to the ceiling Indoor Unit Outline 380 Hooked Part 380 998 322 119 130 65 65 130 50 Above 12cm to the wall Above 12cm to the wall Above 15cm to the ceiling 325 55 95 95 55 1250 815 257 178 55 58 Pipe...

Страница 6: ...ing of outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount Model A mm B mm 3 5kw 530 290 5 3kw 560 335 6 2kw 590 333 A B Air inlet Air outlet Air inlet Drain joint installation If a drain elbow is used the unit should be placed on a stand which is taller than 3cm If the unit is used in an area where temperature falls below 0O C for...

Страница 7: ...ing section C Tape the tubing drain hose and the connecting cable Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Note If the drain hose is routed inside the room insulate the hose with insulation material so that dripping from sweating condensation will not damage furniture or floors Foamed polyethy...

Страница 8: ...n screw Tubing retainer I Reroute the piping and the drain hose across the back of the chassis for rear left side external passage J Locating the indoor unit Remove the spacer Hook the indoor unit onto the upper portion of the installation plate Engage the hooks of the installation plate into the openings at the rear top of the indoor unit Ensure that the hooks are properly seated on the installat...

Страница 9: ...rcuit diagram posted on the inside of the control cover 2 The screws which fasten the wiring in the casing of electrical fittings may come loose from vibrations to which the unit is subjected during the course of transportation Check them and make sure that they are all tightly fastened If they are loose it could cause burn out of the wires 3 Specification of power source 4 Confirm that electrical...

Страница 10: ...an the atmosphere pressure 7 Remove the charge hose from the Low pressure charge hose 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Manifold valve Compound meter 76cmHg Handle L o Handle Hi Charge hose Charge hose Vacuum pump Pressure gauge Low pressure valve Air purging Air purging Air and moisture in the refrigerant system have undesirable effects as ...

Страница 11: ...AUTO or COOL mode see User Manual for details The test operation should last about 30 minutes Manual control button AUTO COOL Rated Capacity Test Cooling mode Under Cooling Mode set the air conditioner at High Fan Speed and set the temperature to 17O C then press the TURBO button 6 times within 10 seconds be sure the indoor unit buzzes 6 times The system will enter Rated Capacity Test mode The buz...

Страница 12: ...rchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and t...

Страница 13: ...rmation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: