![Kellyco DFX Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/kellyco/dfx/dfx_user-manual_662439049.webp)
48
Chapter 5 DFX
™
Pro Options
(Display section)
26. Accumulate
ON combines SignaGraph
®
information over mul-
tiple loop passes, OFF shows SignaGraph
®
informa-
tion only from the last sweep of the loop.
Accumulate allows the SignaGraph
®
to continually
collect information. This collecting of information
continues from one sweep of the loop to the next.
Eventually, if only ACCUMULATE is selected,
the SignaGraph
®
will completely fi ll, requiring that
the TRIGGER be squeezed and released to clear it
so that further information may be viewed. FADE
is suggested to be used in combination with AC-
CUMULATE so that noncurrent information gradu-
ally disappears and excessive TRIGGERing is not
required. FADE will gradually reset or clear the
SignaGraph
®
to eliminate old information.
Tips -
ON is suggested,
since it takes several
sweeps of information to
recognize trends.
27. Average
Emphasizes the most common or predominate Sig-
naGraph
®
indications.
AVERAGE
does not
necessarily allow showing of
does not
does not
all the available information on the SignaGraph
®
. It
averages
the information received, and shows this
average on the SignaGraph
®
. When used in com-
bination with ACCUMULATE it has more infor-
mation to average, which results in more accurate
indications of trends. FADE is suggested to clear
the display of old information, rather than excessive
TRIGGERing.
Tips -
Most benefi cial
when used in combination
with ACCUMULATE. AV-
ERAGE ON is suggested
as it reduces indications
uncharacteristic of a par-
ticular target, which may
occur due to loop angle
or target positioning in the
ground.
(Display section)
If ACCUMULATE is OFF, and AVERAGE
is OFF, then SINGLE SWEEP is active.
SINGLE SWEEP displays SignaGraph
®
information received during the current sweep
of the loop, no more and no less. The next
sweep of the loop will clear all information
from the SignaGraph
®
and list the information
received only within that sweep. Fade is not
needed in the SINGLE SWEEP mode as each
pass of the loop will clear the display and pro-
vide current information automatically. Sev-
eral SignaGraph
®
indication samples occur
during each sweep of the loop. It is therefore
normal to see one or more SignaGraph
®
bars,
even in the SINGLE SWEEP mode.