Operating manual PT 11x, 12x,13x
49
29
Technical Data PT 129 AF 10
Measuring range:
150 ... 800 °C
Sensors:
photo diode
Spectral sensitivity:
1.8
– 2.2 µm
Response time t
98
:
≤ 50 ms (T > 150 °C)
≤ 2 ms (T > 200 °C)
≤ 2 ms (T> 350 °C
Measuring uncertainty:
0.75 % of range and but at
least 5 K
(ε =1.0 and T
A
=23
°C)
Repeatability:
1 K
Temperature coefficient with
reference to 23 °C:
0.25 K / K (for T < 500 °C)
0.05 % / K (for T ≥ 500 °C)
of measured value
29.1 Field of View Diagram for PT 129 AF 10
PT 129
Lens
Focussing range
Distance to target
size ratio
AF 10
PZ 20.08
0.3 m -
48:1
1
2
3
4
5
6
7
8
9
10
21
42
63
83
104
125
146
167
188
208
D = 48 :1
Target Distance [m]
Target diameter [mm]
0
PZ 20.08 (0.3 m -
∞)
6.3