31
EN
Operating instructions CellaCast PX 8x
Plausibility (
t.FAL
)
Threshold for plausibility check: lower limit which is
acceptable for a valid measurement�
Plausibility (
t.riS
)
Threshold for plausibility check: upper limit which is
acceptable for a valid measurement�
When sampling is completed, the average temperature value or „0“ will be output�
At the same time, an impulse is generated which can be used for the digital out-
puts� Enter M�TR�1 as source and set the holt time to 0�5 sec�
A cut-off interval (time lag) begins after the sampling time has ended� This cut-off
interval must expire before the next measurement can start with the cycle starting
conditions described above�
Cut-off interval
(
T.DIS
)
The interval between one completed sampling and
the start of a new sampling�
If a measuring cycle does not start during the period T�OUT, the saved average will
be deleted and reinitialized when the next cycle begins�
Timeout (
T.OUT
)
Timeout für Mittelfunktion (in Minuten)
Activate auto reset for the ATD function to run cyclically� Limit 1 will then be
ignored� Measurement continues when the Limit 2 is exceeded for the period
configured with T�DEL�
Auto reset (
t.AUT
)
Auto reset on/off
The parameter Set Li2 checks on T� ACT checks, whether the value falls below
threshold 2 during the measuring time� If the value falls below the threshold, the
measurement is rejected� The display shows „– – – –“�
Set Li2 check on tAct
(
t.L.2
)
on/off