Operating Manual AmbiCube
Disassembly
Page 34 of 40
Version: 2 | en
Subject to technical changes
11 Disassembly
DANGER
Tension at electrical components.
Death or heavy injuries by electric shock.
a)
Save system shutdown.
b)
Disconnect system from electric power supply.
c)
Discharge electrical resiudal energy entirely prior to disas-
sembly.
CAUTION
Incorrect disassembly
Risk of injury and health hazards.
a)
Depending on the characteristics of the material to be extrac-
ted shall be worn a suitable safety equipment.
b)
Safety gloves shall be worn especially for the disassambly of
edgy and sharp components.
c)
Secure components against turning over or falling down.
d)
Secure components against turning over or falling down.
Prior to starting the disassembly:
1.) Save system shutdown.
2.) Disconnect system from power supply.
3.) Disconnect system from compressed air net.
4.) Discharge residual energy, especially release existing pressure and electrical
residual voltage.
5.) Clean all dirty components.
Provide enough space. Carry out a professional disassembly and classify the com-