Important Safety Information
This product requires a hot and a cold water supply in addition to
an electrical connection (see Electrical section on page 16 & 17
for details). This product is not an electric shower.
Products manufactured by Kelda Showers are safe and without
risk provided they are installed, used and maintained
in accordance with our instructions and recommendations.
DO NOT operate the unit if the showerhead becomes damaged.
DO NOT restrict flow out of shower by placing an obstruction in
front of the showerhead nozzles.
DO NOT allow children to play with the shower
DO NOT allow children to use the shower without supervision
General
1.
Read all of these instructions before installation and retain
them for later use.
2.
DO NOT take risks with plumbing or electrical equipment.
3.
Isolate electrical and water supplies before proceeding with
the installation.
4.
The showerhead must be cleaned regularly with descalant
to remove scale and debris (see Maintenance section on
page 21).
5.
This product is not suitable for mounting into steam rooms
or steam cubicles.
6.
The shower should not be installed in an outdoor
environment, including sheltered areas.
7.
DO NOT spray water at the BubbleSpa showerhead as this
risks damaging the electronics.
Plumbing
1.
The plumbing installation must comply with water
regulations, building regulations or any particular regulations
as specified by local water company or water undertakers
and should be in accordance with BS EN 806 (Specifications
for installations inside buildings conveying water for human
consumption. Operation and maintenance).
2.
IMPORTANT! The hot and cold-water supply pipes must be
flushed to clear debris from before connecting to water inlets
on the shower.
3.
DO NOT use excessive force when making connections to
the mixer.
4.
All plumbing connections must be completed before making
the electrical connections.
5.
Water Pressure: A 2 bar system is recommended as a
minimum, if using a low pressure (Gravity fed) system a
suitable pump will be required. Your BubbleSpa shower is
designed to perform best between 8-10L/min and will not
produce bubbles with a flow rate below 6L/min. Using the
BubbleSpa shower without a Kelda supplied flow regulator
will void the warranty and negatively affect the performance
of the product.
Electrical
1.
The installation must comply with BS 7671 ‘Requirements
for electrical installations’ (IEE wiring regulations), building
regulations or any particular regulations as specified by the
local electrical supply company.
2.
In accordance with ‘The Plugs and Sockets etc. (Safety)
Regulations 1994’, this appliance is intended to be
permanently connected to the fixed wiring of the electrical
mains system.
3.
A 32A 30 mA Residual Current Breaker Operator (RCBO)
MUST be installed in all UK electric and pumped shower
circuits. This may be part of the consumer unit or a separate
unit.
4.
Each shower must be connected to a 3A switched fused
spur which is easily accessible. Switch off at fused spur
for maintenance or if not in use for extended periods. This
is a safety procedure recommended with all electrical
appliances.
5.
Make sure all electrical connections are tight to prevent
overheating.
6.
As with all electrical appliances it is recommended to have
the shower and installation checked at least every two years
by a competent electrician to ensure there is no deterioration
due to age and usage.
Flashing Lights
To enhance the visual impact of the bubbles this shower uses
flashing light effects, with a minimum frequency of 72Hz. This
is accordance with safety guidance from the IEEE (IEEE
1789-2015) and is safely above the 3-30Hz range (commonly
identified as values to be avoided for people with photosensitive
conditions).
The visual effect of the lighting modes will vary depending on
ambient lighting and the environment in which it is installed (see
page 20 for more details on Bubble Modes).
Anyone diagnosed with a condition which could be triggered by
flashing lights should seek further medical advice.
3
Содержание BubbleSpa 95005000
Страница 1: ......
Страница 4: ...System Diagram BubbleSpa Exposed Wall Arm with Shelf 300 130 300 1101 55 360 50 614 464 20 182 970 4...
Страница 9: ...Installation 9...
Страница 28: ...Cut out for installing the Handset Holder 28...