Important Safety Information

This product requires a hot and a cold water supply in addition to 

an electrical connection (see Electrical section on page 16 & 17 

for details). This product is not an electric shower.

Products manufactured by Kelda Showers are safe and without 

risk provided they are installed, used and maintained

in accordance with our instructions and recommendations.

DO NOT operate the unit if the showerhead becomes damaged.

DO NOT restrict flow out of shower by placing an obstruction in 

front of the showerhead nozzles.

DO NOT allow children to play with the shower

DO NOT allow children to use the shower without supervision

General

1. 

Read all of these instructions before installation and retain 

them for later use.

2. 

DO NOT take risks with plumbing or electrical equipment.

3. 

Isolate electrical and water supplies before proceeding with 

the installation.

4. 

The showerhead must be cleaned regularly with descalant 

to remove scale and debris (see Maintenance section on 

page 21).

5. 

This product is not suitable for mounting into steam rooms 

or steam cubicles.

6. 

The shower should not be installed in an outdoor 

environment, including sheltered areas.

7. 

DO NOT spray water at the BubbleSpa showerhead as this 

risks damaging the electronics.

Plumbing

1. 

The plumbing installation must comply with water 

regulations, building regulations or any particular regulations 

as specified by local water company or water undertakers 
and should be in accordance with BS EN 806 (Specifications 

for installations inside buildings conveying water for human 

consumption. Operation and maintenance).

2. 

IMPORTANT! The hot and cold-water supply pipes must be 
flushed to clear debris from before connecting to water inlets 

on the shower.

3. 

DO NOT use excessive force when making connections to 

the mixer.

4. 

All plumbing connections must be completed before making 

the electrical connections.

  

5. 

Water  Pressure:  A  2  bar  system  is  recommended  as  a 
minimum,  if  using  a  low  pressure  (Gravity  fed)  system  a 
suitable pump will be required. Your BubbleSpa shower is 
designed  to  perform  best  between  8-10L/min  and  will  not 
produce bubbles with a flow rate below 6L/min. Using the 
BubbleSpa shower without a Kelda supplied flow regulator 

will void the warranty and negatively affect the performance 

of the product.

Electrical

1. 

The installation must comply with BS 7671 ‘Requirements 
for electrical installations’ (IEE wiring regulations), building 
regulations or any particular regulations as specified by the 

local electrical supply company.

2. 

In  accordance  with  ‘The  Plugs  and  Sockets  etc.  (Safety) 
Regulations  1994’,  this  appliance  is  intended  to  be 
permanently connected to the fixed wiring of the electrical 

mains system. 

3. 

A 32A 30 mA Residual Current Breaker Operator (RCBO) 
MUST  be  installed  in  all  UK  electric  and  pumped  shower 

circuits. This may be part of the consumer unit or a separate 

unit.

4. 

Each  shower  must  be  connected  to  a  3A  switched  fused 
spur  which  is  easily  accessible.  Switch  off  at  fused  spur 

for maintenance or if not in use for extended periods. This 

is a safety procedure recommended with all electrical 

appliances.

5. 

Make sure all electrical connections are tight to prevent 

overheating.

6. 

As with all electrical appliances it is recommended to have 

the shower and installation checked at least every two years 

by a competent electrician to ensure there is no deterioration 

due to age and usage.

Flashing Lights

To enhance the visual impact of the bubbles this shower uses 

flashing light effects, with a minimum frequency of 72Hz.  This 
is  accordance  with  safety  guidance  from  the  IEEE  (IEEE 
1789-2015)  and  is  safely  above  the  3-30Hz  range  (commonly 
identified as values to be avoided for people with photosensitive 

conditions). 

The  visual  effect  of  the  lighting  modes  will  vary  depending  on 

ambient lighting and the environment in which it is installed (see 

page 20 for more details on Bubble Modes). 

Anyone diagnosed with a condition which could be triggered by 

flashing lights should seek further medical advice. 

3

Содержание BubbleSpa 95005000

Страница 1: ......

Страница 2: ...forefront of luxury showering Kelda is injecting magic into the showering experience to transform the everyday bathroom into a place of personal sanctuary and tranquility Kelda s unique BubbleRain sp...

Страница 3: ...bar system is recommended as a minimum if using a low pressure Gravity fed system a suitable pump will be required Your BubbleSpa shower is designed to perform best between 8 10L min and will not pro...

Страница 4: ...System Diagram BubbleSpa Exposed Wall Arm with Shelf 300 130 300 1101 55 360 50 614 464 20 182 970 4...

Страница 5: ...em Diagram BubbleSpa Exposed Wall Arm with Shelf 290 62 110 124 134 10 Max tilt of Ball Joint Tilting of the BubbleSpa showerhead can be in any direction All dimensions are in mm unless otherwise stat...

Страница 6: ...9 10 11 2 1 12 4 7 No Part Qty 1 Exposed Arm Assembly 1 2 BubbleSpa Showerhead 1 3 Exposed Shelf 1 4 Wall Plugs 10 5 Bracket Pad 2 6 Fixing Bracket 2 7 Wall Screws 10 8 Collar 2 9 Filter 2 10 Grub Sc...

Страница 7: ...ubbleSpa Showerhead x1 Exposed Arm Assembly x2 Arm Screw May be partially screwed into arm x1 Wall Bracket x2 Retaining Screw x1 Power Supply x1 Shelf Mixer x2 M3 Grub Screw BubbleSpa Exposed Your Bub...

Страница 8: ...Shower Hose x1 Handset Holder x2 Mounting Bracket x2 Wall Plugs x2 Wall Screws x1 Grub Screws x1 Hole Guide cut out from page 28 4 5 Handset x2 Filters x1 Alignment Tool x2 Fixing Bracket x2 Bracket P...

Страница 9: ...Installation 9...

Страница 10: ...nstallation This is a critical dimension The holes at the top are slots allowing for variance of 5mm 20 20 1111 150 25 30 1001 900 1000 typical outlet height to the floor 1900 2000 Cold Inlet Hot Inle...

Страница 11: ...between the tiles and Fixing brackets to protect the wall The Alignment Tool can be used to assist with drilling the holes and attaching the screws 3 If the Alignment Tool was used remove it Insert a...

Страница 12: ...ollars Ensure the Shelf Mixer is flush against the wall If the Shelf Mixer is not flush it may be because the inlet pipes from the wall are too long If so cut the inlet pipes to length and fit the She...

Страница 13: ...or the Handset Holder Then Place the Wall Plugs inside the holes and screw the Mounting Brackets onto the wall using the Wall Screws 10 Feed the power cable of the Exposed Arm Assembly into the wall t...

Страница 14: ...the hose and the flow regulator is inside the Handset before attaching 15 The installation of the Handset is complete Place the Handset onto the Handset Holder Run the showerhead without power to test...

Страница 15: ...as consistently below 20 C Once you are satisfied with the bubbles remove the protective film from the faceplate and enjoy your BubbleSpa shower Once the power is turned on the Button Light on the sh...

Страница 16: ...t by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO 3A Switched...

Страница 17: ...nment Working Temp Tcase 35 70 C Max Case Temp Tcase 70 C Working Humidity 20 95 RH non condensing Storage Temp Humidity 40 80 C 10 95 RH Temp Coefficient 0 03 C 0 50 C Vibration 10 500Hz 5G 12min 1cy...

Страница 18: ...rotating the temperature control knob on the far right of the Shelf Mixer Turn anti clockwise to increase the temperature and turn clockwise to decrease the temperature The default temperature should...

Страница 19: ...hower Wet working mode is automatically activated when water flows through the BubbleSpa head The default light setting is 1 Low see table below The BubbleSpa shower will return to this setting in the...

Страница 20: ...t least 5 seconds to engage the diagnostic tool During this function the main light array and the fan will turn on To switch off the fan and light simply let go of the button Use this tool to check th...

Страница 21: ...clean with a soft cloth and if necessary a mild cleaning or descaling solution can be used Always remove cleaning agent residue as this can discolour the surface Care must be taken not to allow bleac...

Страница 22: ...assemblies Using the BubbleSpa shower without a PCB Cover or Dust Cover with Dust Filters Be careful not allow water into the fan when Fitting Removing the BubbleSpa showerhead Spraying any additional...

Страница 23: ...ter Place the new flow regulator ensure that the orientation of the flow regulator is correct Then place the filter back and screw the BubbleSpa shower back onto the Arm Assembly The BubbleSpa shower...

Страница 24: ...a damp cloth to remove the loosened debris 3 4 Run the shower for 1 2 minutes to flush out any cleaning solution and debris The frequency of the maintenance required is dependent on the usage and the...

Страница 25: ...Fan Damaged Debris in fan Check power light indicator if off contact a qualified electrician If power light indicator is on conduct hard reset by switching off electrical supply and waiting 10 seconds...

Страница 26: ...s can be returned within one month from date of purchase providing that they are in good order and the packaging is unopened Note returned spares will be subject to a 15 restocking charge and authoris...

Страница 27: ...Trading Estate Chandler s Ford Eastleigh SO53 4DR UK Tel 44 0 2381 290640 Web www keldatechnology com DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with y...

Страница 28: ...Cut out for installing the Handset Holder 28...