Output
DC Voltage
24V
Constant Current Region
13.2 ~ 24V
Rated Current
1.05A
Rated Power
25.2W
Input
Voltage Range
90 ~ 305VAC
Frequency Range
47 ~ 63Hz
AC Current
0.4A / 115VAC
0.25A / 230VAC
0.2A / 277VAC
Electrical Installation
Meanwell Customised 24V LPF Series Unit
Protection
Over Current
95-108%
Constant current limiting, recovers automatically after fault condition is
removed
Short Circuit
Hiccup mode, recovers automatically after fault condition is removed
Over Voltage
28-35V
Shut down and latch off o/p voltage, re-power on to recover
Over Temperature
Shut down o/p voltage, recovers automatically after temperature goes down
Environment
Working Temp.
Tcase= -35~+70°C
Max. Case Temp.
Tcase= +70°C
Working Humidity
20 ~ 95% RH non-condensing
Storage Temp. Humidity -40 ~+80°C, 10 ~ 95% RH
Temp. Coefficient
+/-0.03%/°C (0 ~ 50°C)
Vibration
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety & EMC
Safety Standards
UL8750, CSA C22.2 No.250.0-08; ENEC BS EN/EN61347-2-13 independent,
BS EN/EN62384, J61347-2-13, EAC TPTC 004, GB19510.14, IP67
approved; Design refer to UL60950-1
Withstand Voltage
I/P-O/P:3.75KVAC
Isolation Resistance I/P-O/P: 100M Ohms / 500VDC / 25°C / 70% RH
EMC Emmission
Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≥50%)
; BS EN/EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020
EMC Immunity
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light
industry level (surge immunity Line-Line 2KV), EAC TP TC 020
IP67 - Fully Encapsulated