Troubleshooting

BubbleSpa Showerhead

Before  troubleshooting,  ensure  that  the  correct  installation,  usage  and  maintenance  procedures  have  been  followed. 

Improper installation and improper use of the product can cause a lot of issues. The guide below is designed to help identify 

and solve minor issues which may occur. If the issue is still not resolved, please contact Kelda Customer Service: 

[email protected] 
+44 (0)2381 290640

DO NOT

 disassemble the BubbleSpa showerhead beyond the instructions contained in this manual. Disassembling the 

BubbleSpa showerhead will invalidate the warranty.

Symptom

Likely Cause

Action/ Remedy

Poor/ No water flow:

Hot or cold water supply isolation 

valve closed

Blocked filter

Mixer valve not functioning.

Check and open valve

Unscrew the BubbleSpa showerhead from 
the arm, remove and clean filter, replace filter. 
Clean the mixer valve filter

Check mixer valve

Water flows from showerhead
but no air:

No power to the fan

 

Fan Damaged

Debris in fan

Check power light indicator, if off contact a 
qualified electrician

If power light indicator is on, conduct hard 

reset by switching off electrical supply and 
waiting 10 seconds before turning on.

Use Diagnostic Function to see if the fan is 

working. If not, contact Kelda

Clean the Dust Filters

One/ a few nozzles aren’t 
making bubbles:

No laminar flow through nozzle

Faulty nozzle is blocked

Insufficient water supply

Gently brush a finger against the nozzle whilst 

the shower is running

Descale the showerhead to remove debris 

(see page 23). Check the filter is installed 

correctly (both the showerhead and valve) and 

clean

Increase the water flow to the shower.

Multiple/ all nozzles aren’t 

making bubbles

Insufficient water supply

Limescale/ Debris build up in the 

nozzles

The fan wont turn on below 6L/min therefore 

no bubbles will be produced. Increase the 

water flow to the shower.

Clean the BubbleSpa showerhead (see 

page 23). It is reccomended not to leave the 

BubbleSpa showerhead unused for more than 

2 weeks.

Water flow too strong:

Flow restrictor not installed.

Check if the flow restrictor is properly installed 

(see page 23)

25

Содержание BubbleSpa 95005000

Страница 1: ......

Страница 2: ...forefront of luxury showering Kelda is injecting magic into the showering experience to transform the everyday bathroom into a place of personal sanctuary and tranquility Kelda s unique BubbleRain sp...

Страница 3: ...bar system is recommended as a minimum if using a low pressure Gravity fed system a suitable pump will be required Your BubbleSpa shower is designed to perform best between 8 10L min and will not pro...

Страница 4: ...System Diagram BubbleSpa Exposed Wall Arm with Shelf 300 130 300 1101 55 360 50 614 464 20 182 970 4...

Страница 5: ...em Diagram BubbleSpa Exposed Wall Arm with Shelf 290 62 110 124 134 10 Max tilt of Ball Joint Tilting of the BubbleSpa showerhead can be in any direction All dimensions are in mm unless otherwise stat...

Страница 6: ...9 10 11 2 1 12 4 7 No Part Qty 1 Exposed Arm Assembly 1 2 BubbleSpa Showerhead 1 3 Exposed Shelf 1 4 Wall Plugs 10 5 Bracket Pad 2 6 Fixing Bracket 2 7 Wall Screws 10 8 Collar 2 9 Filter 2 10 Grub Sc...

Страница 7: ...ubbleSpa Showerhead x1 Exposed Arm Assembly x2 Arm Screw May be partially screwed into arm x1 Wall Bracket x2 Retaining Screw x1 Power Supply x1 Shelf Mixer x2 M3 Grub Screw BubbleSpa Exposed Your Bub...

Страница 8: ...Shower Hose x1 Handset Holder x2 Mounting Bracket x2 Wall Plugs x2 Wall Screws x1 Grub Screws x1 Hole Guide cut out from page 28 4 5 Handset x2 Filters x1 Alignment Tool x2 Fixing Bracket x2 Bracket P...

Страница 9: ...Installation 9...

Страница 10: ...nstallation This is a critical dimension The holes at the top are slots allowing for variance of 5mm 20 20 1111 150 25 30 1001 900 1000 typical outlet height to the floor 1900 2000 Cold Inlet Hot Inle...

Страница 11: ...between the tiles and Fixing brackets to protect the wall The Alignment Tool can be used to assist with drilling the holes and attaching the screws 3 If the Alignment Tool was used remove it Insert a...

Страница 12: ...ollars Ensure the Shelf Mixer is flush against the wall If the Shelf Mixer is not flush it may be because the inlet pipes from the wall are too long If so cut the inlet pipes to length and fit the She...

Страница 13: ...or the Handset Holder Then Place the Wall Plugs inside the holes and screw the Mounting Brackets onto the wall using the Wall Screws 10 Feed the power cable of the Exposed Arm Assembly into the wall t...

Страница 14: ...the hose and the flow regulator is inside the Handset before attaching 15 The installation of the Handset is complete Place the Handset onto the Handset Holder Run the showerhead without power to test...

Страница 15: ...as consistently below 20 C Once you are satisfied with the bubbles remove the protective film from the faceplate and enjoy your BubbleSpa shower Once the power is turned on the Button Light on the sh...

Страница 16: ...t by an approved electrician in accordance with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO 3A Switched...

Страница 17: ...nment Working Temp Tcase 35 70 C Max Case Temp Tcase 70 C Working Humidity 20 95 RH non condensing Storage Temp Humidity 40 80 C 10 95 RH Temp Coefficient 0 03 C 0 50 C Vibration 10 500Hz 5G 12min 1cy...

Страница 18: ...rotating the temperature control knob on the far right of the Shelf Mixer Turn anti clockwise to increase the temperature and turn clockwise to decrease the temperature The default temperature should...

Страница 19: ...hower Wet working mode is automatically activated when water flows through the BubbleSpa head The default light setting is 1 Low see table below The BubbleSpa shower will return to this setting in the...

Страница 20: ...t least 5 seconds to engage the diagnostic tool During this function the main light array and the fan will turn on To switch off the fan and light simply let go of the button Use this tool to check th...

Страница 21: ...clean with a soft cloth and if necessary a mild cleaning or descaling solution can be used Always remove cleaning agent residue as this can discolour the surface Care must be taken not to allow bleac...

Страница 22: ...assemblies Using the BubbleSpa shower without a PCB Cover or Dust Cover with Dust Filters Be careful not allow water into the fan when Fitting Removing the BubbleSpa showerhead Spraying any additional...

Страница 23: ...ter Place the new flow regulator ensure that the orientation of the flow regulator is correct Then place the filter back and screw the BubbleSpa shower back onto the Arm Assembly The BubbleSpa shower...

Страница 24: ...a damp cloth to remove the loosened debris 3 4 Run the shower for 1 2 minutes to flush out any cleaning solution and debris The frequency of the maintenance required is dependent on the usage and the...

Страница 25: ...Fan Damaged Debris in fan Check power light indicator if off contact a qualified electrician If power light indicator is on conduct hard reset by switching off electrical supply and waiting 10 seconds...

Страница 26: ...s can be returned within one month from date of purchase providing that they are in good order and the packaging is unopened Note returned spares will be subject to a 15 restocking charge and authoris...

Страница 27: ...Trading Estate Chandler s Ford Eastleigh SO53 4DR UK Tel 44 0 2381 290640 Web www keldatechnology com DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with y...

Страница 28: ...Cut out for installing the Handset Holder 28...

Отзывы: