Important safety Information
This product requires hot and cold water supply plus an
electrical connection (see Electrical section on page 10 for
details). This product is not an electric shower.
Products manufactured by Kelda Technology are safe and
without risk provided they are installed, used and maintained
in good working order in accordance with our instructions and
recommendations.
DO NOT operate the unit if the shower head becomes
damaged.
DO NOT restrict flow out of shower by placing an obstruction in
front of the shower head nozzles.
DO NOT allow children to play with thew shower
DO NOT allow children to use the shower without supervision
General
1.
Read all of these instructions and retain them for later use.
2.
DO NOT take risks with plumbing or electrical equipment.
3.
Isolate electrical and water supplies before proceeding with
the installation.
4.
The shower head must be cleaned regularly with descalant
to remove scale and debris. PLEASE SEE MAINTENANCE
SECTION.
5.
This product is not suitable for mounting into steam rooms
or steam cubicles.
6.
The shower should not be installed in an outdoor
environment, including sheltered areas.
Plumbing
1.
The plumbing installation must comply with water
regulations, building regulations or any particular
regulations as specified by local water company or
water undertakers and should be in accordance with BS
EN 806 (Specifications for installations inside buildings
conveying water for human consumption. Operation and
maintenance).
2.
IMPORTANT! The hot and cold-water supply pipes must
be flushed to clear debris from before connecting to water
inlets on shower.
3.
DO NOT solder pipes or fittings within the panel shower,
this could result in damage to the product. Use push fit or
compression fittings.
4.
DO NOT use excessive force when making connections to
the mixer.
5.
All plumbing connections must be completed beforemaking
the electrical connections.
6.
Water pressure. Kelda products are designed to operate up
to a maximum of 5 bar, if you wish to operate outside of this
please discuss with a Kelda Engineer.
Electrical
1.
The installation must comply with BS 7671 ‘Requirements
for electrical installations’ (IEE wiring regulations), building
regulations or any particular regulations as specified by the
local electrical supply company.
2.
In accordance with ‘The Plugs and Sockets etc. (Safety)
Regulations 1994’, this appliance is intended to be
permanently connected to the fixed wiring of the electrical
mains system.
3.
A 32A 30 mA Residual Current Breaker Operator (RCBO)
MUST be installed in all UK electric and pumped shower
circuits. This may be part of the consumer unit or a
separate unit.
4.
Each shower must be connected to a 3A switched fused
spur which is easily accessible. Switch off at fused spur
for maintenance or if not in use for extended periods. This
is a safety procedure recommended with all electrical
appliances.
5.
Make sure all electrical connections are tight to prevent
overheating.
6.
As with all electrical appliances it is recommended to
have the shower and installation checked at least every
two years by a competent electrician to ensure there is no
deterioration due to age and usage.
Lighting
BEWARE, this product uses a strobing effect at 72Hz. Should
anyone begin to feel unwell whilst using the strobing effect,
users are advised to switch to higher. Please see page x for
more details.