![kelda 95001000 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/kelda/95001000/95001000_installation-manual-and-users-manual_3963647017.webp)
Electrical Installation
This shower requires a 100-240 VAC, 47 ~ 63Hz single phase supply. A single 3 Amp switched fused spur should be used
for each Panel. Up to 12 Kelda showers can run from a single 32A 30mA RCBO.
Before connecting to power supply, make sure that the mains terminal is able to sustain 240V and 3A.
All electrical installation to
be carried out by an approved electrician in accordance with Part “P” U.K. Building Regulations and to the latest IEEE
standards, or the appropriate regulations in the country of installation.
~~
~~
~~
~~
32A 30mA RCBO
3A Switched Fused Spur
AC 220-240V to DC
24V Transformer 25.2W
(Supplied)
Bubble head
Main Distribution Board
100-240V AC
Electrical
connection
(Ariel View)
41