Resetting Valve Temperature
Maintenance
Changing Flow Regulator (Flow Restrictor)
The BubbleSpa shower comes with a 10L/min flow regulator. This can be changed by unscrewing the BubbleSpa shower
from the Threaded Adaptor and removing the flow regulator from inside the Ball Joint. The Flow Regulator is underneath
the strainer. Place the new flow regulator, ensure that the orientation of the flow regulator is correct. Then place the
strainer and screw the BubbleSpa shower back onto the threaded adaptor. The BubbleSpa shower operates at a range of
6L/min – 12L/min.
1
Keep the 2 red lines colinear whilst turning the spindle. Turn
the spindle anti-clockwise to reduce the water temperature
(or turn the spindle clockwise to increase the temperature.
Measure the temperature of the water and adjust as required.
2
Remove the screw, handle adaptor and temperature control ring
from thermostatic cartridge (on a dual valve this is the bottom
cartridge& on a triple valve this is the middle cartridge).
51