Section 5: SCPI command reference
Series 2230G Triple-Channel Power Supplies User's Manual
5-2
2230G-900-01 Rev. A / June 2018
Mnemonic
Name
Description
*CLS
Clear status
Clear all the event registers and error queue.
*ESE <NRf>
Event enable command
Edit the Standard Event Enable Register.
*ESE?
Event enable query
Read the Standard Event Enable Register.
*ESR?
Event status query
Read the Standard Event Status Register and clear it.
*IDN?
Identification query
Return the instrument manufacturer, model, serial number,
and firmware revision level.
*OPC
Operation complete command
Set the Operation Complete bit in the Standard Event Status
Register after all pending commands have been executed.
*OPC?
Operation complete query
Place an ASCII
1
into the output queue when all pending
selected device operations have been completed.
*RCL <NR1>
Recall command
Return the power supply setup configuration stored in the
specified memory location.
*RST
Reset command
Returned the power supply to the
*RST
default conditions.
*SAV <NR1>
Save command
Save the present setup to the specified memory location.
*SRE <NR1>
Service request enable command Program the Service Request Enable Register.
*SRE?
Service request enable query
Read the Service Request Enable Register.
*STB?
Read status byte query
Read the Status Byte Register.
*TST?
Self-test query
Execute self-test and return a result.
*WAI
Wait to continue command
Wait until all previous commands are executed.
*CLS (no query form)
This command clears the bits of the Standard Event Register, Operation Event Register, and Questionable Event
Register and clears the error queue.
Group
Status
Syntax
*CLS
Arguments
None
Returns
Not applicable
Example
*CLS
Clears the event registers and error queue.
See also
(on page 5-3)
(on page 5-9)