Section 5: SCPI command reference
Series 2230G Triple-Channel Power Supplies User's Manual
5-34
2230G-900-01 Rev. A / June 2018
Default value
0.1
Returns
0.1
to
99999.9
Example
OUTP:TIM:DEL 10
You can use
*RST
to reset the timer to
0.1
s.
See also
(on page 5-7)
[SOURce:]OUTPut:TIMer[:STATe]
This command sets the output timer state for the presently selected channel. The query version of this command
returns the output timer state for the presently selected channel.
Group
Source
Syntax
[SOURce:]OUTPut:TIMer[:STATe] <BOOL>
[SOURce:]OUTPut:TIMer[:STATe]?
Arguments
<BOOL> ON|OFF|0|1
The output timer state.
Default value
OFF
Returns
0|1
0
Turns the output timer state to
OFF
.
1
Turns the output timer state to
ON
.
Example
OUTP:TIM ON
Sets the output timer state to
ON
.
See also
None