IEEE-488 Reference
3-64
:ARM[:SEQuence[1]]
[:LAYer[1]]
:IMMediate
:COUNt <n>
:COUNt?
:SOURce <name>
:SOURce?
:SIGNal
:TCONfigure
:DIRection <name>
:DIRection?
:ASYNchronous
:ILINe <NRf>
:ILINe?
:OLINe <NRf>
:OLINe?
:RTCLock
:DATE <yr>, <mo>, <day>
:DATE?
:TIME <hr>, <min>, <sec>
:TIME?
:LAYer2
:IMMediate
:COUNt <n>
:COUNt?
:DELay <n>
:DELay?
:SOURce <name>
:SOURce?
:TIMer <n>
:TIMer?
:SIGNal
:TCONfigure
:DIRection <name>
:DIRection?
:ASYNchronous
:ILINe <NRf>
:ILINe?
:OLINe <NRf>
:OLINe?
:TRIGger[:SEQuence[1]]
:IMMediate
:COUNt <n>
:COUNt?
:DELay <n>
:DELay?
:SOURce <name>
:SOURce?
Path to configure arm layers:
Path to program Arm Layer 1:
Loop around control source.
Specify arm count (1 to 99999, or INF).
Query arm count.
Select control source (HOLD, IMMediate, RTCLock,
MANual, BUS, TLINk or EXTernal).
Query control source.
Loop around control source.
Path to configure Triggers:
Enable (SOURce) or disable (ACCeptor).
Query direction.
Path to configure asynchronous Trigger Link:
Select input line (1 to 6).
Query input line.
Select output line (1 to 6).
Query output line.
Path to configure the RTCLock control source:
Specify the date for the clock event.
Query the date for the clock event.
Specify the time for the clock event.
Query the time for the clock event.
Path to program Arm Layer 2:
Loop around control source.
Specify scan count (1 to 99999 or INF).
Query scan count.
Program delay (0 to 999999.999 sec).
Query delay.
Select control source (HOLD, IMMediate, TIMer,
MANual, BUS, TLINk or EXTernal).
Query control source.
Set timer interval (0.001 to 999999.999 sec).
Query timer.
Loop around control source.
Path to configure Triggers:
Enable (SOURce) or disable (ACCeptor) Bypass.
Query direction.
Path to configure asynchronous Trigger Link:
Select input line (1 to 6).
Query input line.
Select output line (1 to 6).
Query output line.
Path to program Trigger Layer:
Loop around control source.
Set measure count (1 to 99999, or INF).
Query measure count.
Set delay (0 to 999999.999 sec).
Query delay.
Select control source (HOLD, IMMediate, TIMer,
MANual, BUS, TLINk or EXTernal).
Query control source.
1
IMMediate
ACCeptor
2
1
(Note 3)
0
IMMediate
1
ACCeptor
2
1
(Note 3)
0
IMMediate
√
√
√
√
√
(Note 2)
√
√
√
√
√
√
√
√
(Note 2)
√
√
√
√
√
√
√
√
√
√
(Note 2)
√
3.23.3
3.23.4
3.23.6
3.23.8
3.23.9
3.23.10
3.23.3
3.23.4
3.23.5
3.23.6
3.23.7
3.23.8
3.23.9
3.23.3
3.23.4
3.23.5
3.23.6
Table 3-15 (Continued)
Trigger command summary
Command
Description
Default
parameter
SCPI
Ref.
Содержание 2002
Страница 123: ...Front Panel Operation 2 106...
Страница 145: ...IEEE 488 Reference 3 22...
Страница 167: ...IEEE 488 Reference 3 44...
Страница 284: ...A Specifications A 1...
Страница 362: ......