background image

        

11 

 

 

    

DOC06179  Rev. B

OWNER / OPERATOR MANUAL

RUNNING FLOOR II

®

 DX / DXE

2.2 

General Wet Kit Specifications

 

Oil:

ISO-L-HM 46 hydraulic oil (As per ISO 11158).

PTO and 

Pump: *

The PTO and Pump must be capable of producing a minimum flow rate of 5 

gal/min at 3000 PSI [19 liters/min at 207 bar] for proper operation. KEITH 

recommends a PTO and Pump capable of producing between 40 and 60 gal/min at 

less than 3000 PSI [151-227 liters/min at less than 207 bar] for optimal operation.  

NOTE:

  Pumps with built-in pressure relief valves are NOT recommended.

See the Wet Kit RUNNING FLOOR II

® 

 document available on the KEITH website 

www.KeithWalkingFloor.com or contact a KEITH Manufacturing Co. representative 

for specific recommendations on selecting a wet kit. 

Do not exceed the maximum flow rate. 

Do not exceed the maximum pressure. 

Filter:

Filter should be double element, 10 to 25 µm, on the return line.

(The filter element should be changed after the initial 6 hours of operation, then 

every 6 months thereafter. This may vary with the operating environment).

Hydraulic 

Reservoir:

Sized to desired flow rate.  Should hold approximately 1 gallon of oil for every gallon 

per minute you plan to pump, i.e. 40 gal/min = 40 gallon reservoir. Minimum 40 

gallons [151 liters] 

Suction Line:

Suction hose from the reservoir tank to the pump should be no more than 5 ft [1.5 m] 

in length and a minimum of 2 inch [51 mm] inside diameter. 

KEITH recommends using SAE100R4 (This type of hose has a spiral wire to keep 

the hose from collapsing under suction).

Pressure Line:

Hose from wet kit to floor should be 1 in [-16] SAE-100R2. 

Return Line:

Hose from floor to wet kit filter should be 1 in [-16] SAE-100R1.

Hose from filter to reservoir tank should be 1¼ in [-20] SAE-100R1.

Pressure 

Relief Valve: *

High quality valve with the ability to relieve full pump flow at 3000 PSI [207 bar].  

NOTE: 

Relief valve must be set above 2800 PSI [193 bar] and no higher than 3000 

PSI [207 bar]

* If the information about your pump and pressure relief valve is not known, have a pressure/flow 

check done by a professional.

Содержание KRFII-3

Страница 1: ...02 Fax 541 475 2169 OWNER OPERATOR MANUAL Original Instructions 2018 KEITH Manufacturing Co All Rights Reserved KEITH KEITH logo and WALKING FLOOR are registered trademarks of KEITH Manufacturing Co E...

Страница 2: ...on 3 1 2 3 Danger Zones 3 1 2 4 Electric Components and Installation 4 1 2 5 Hydraulics 4 1 2 6 Controls 4 1 3 Marking of Machinery 5 1 3 1 Safety Decals 5 1 3 2 Serial Plates 9 2 0 Specifications 10...

Страница 3: ...11 Manual Override of Electric Controls 29 4 0 Maintenance 31 4 1 Life Extending Conditions 31 4 2 Preventative Maintenance 31 4 2 1 Monthly Service 25 operating hours 31 4 2 2 6 Month Service 150 op...

Страница 4: ...t will be needed on your tractor PleasecontactaKEITHManufacturingCo representativeorvisitourwebsitewww KeithWalkingFloor com for more specific recommendations regarding pumps filters and pressure reli...

Страница 5: ...4 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The relevant technical documentation is compiled in accordance with part B of annex VII In response to a reasoned request by national authorities relevant informatio...

Страница 6: ...ts and components are subject to normal wear and tear and are not warranty items Defects in electrical components caused by incorrect connection and or incorrect voltage levels The warranty is void if...

Страница 7: ...KEITH North America South America facility or nearest KEITH Europe facility Please contact KEITH for additional information on proper locations Except As Expressly Set Forth Above KEITH Manufacturing...

Страница 8: ...the manufacture date Name Company Name _______________________________________________________________ Address ____________________________________________________________________________ City State...

Страница 9: ...th state of the art technology and the acknowledged safety regulations Nevertheless dangerous situations could arise from improper use which could endanger life and limbs of personnel and cause severe...

Страница 10: ...ned workstation sound pressure levels emitted by the WALKING FLOOR modules were measured at a height of 1 6 meters from the floor surface and a distance of 1 meter from the surface of the WALKING FLOO...

Страница 11: ...e fill and drain ports for the oil 1 2 Design Installation Safety 1 2 1 Kit Components 1 2 1 1 The kit consists of a drive unit flooring and miscellaneous boxed parts These modules are intended to be...

Страница 12: ...ger zones are visible from the control station 1 2 6 3 An acceptable means must be provided to monitor the status and movement of the load 1 2 6 4 The floor can generate enormous horizontal force whic...

Страница 13: ...5 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE 1 3 Marking of Machinery 1 3 1 Safety Decals...

Страница 14: ...6 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE...

Страница 15: ...7 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE...

Страница 16: ...8 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE...

Страница 17: ...XE 1 3 2 Serial Plates Please fill in the information from the serial plate attached to your drive system Overtime these plates become difficult to read or even locate and this information is crucial...

Страница 18: ...5 5 tonnes 75 tons 68 tonnes Pump Flow Rate 5 60 gal min 19 227 liters min 5 60 gal min 19 227 liters min 5 60 gal min 19 227 liters min Recommended Pump Flow Rate 40 45 gal min 151 170 liters min 40...

Страница 19: ...d after the initial 6 hours of operation then every 6 months thereafter This may vary with the operating environment Hydraulic Reservoir Sized to desired flow rate Should hold approximately 1 gallon o...

Страница 20: ...ler 1 Pressure Hose 2 Suction Hose 1 Pressure Relief Hose Pump 1 1 4 Return Hose 1 Male Quick Coupler 1 Female Quick Coupler Switching Valve Ball Valve PUMP RES RES CYL CYL FLOOR WET KIT PRESSURE FLOW...

Страница 21: ...ge end Stage 1 The first group of slats approximately every 3rd slat moves under the load Load does not move Stage 2 The second group of slats moves under the load Load does not move Stage 3 The final...

Страница 22: ...14 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE 3 2 Oil Flow Diagrams...

Страница 23: ...15 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE...

Страница 24: ...nderneath front stiffener plate Component Location Guide RUNNING FLOOR II DX Manual Controls Left Side Restrictor Valves If Required Ball Valve Manual BV Handle On Off Control Valve Manual CV Handle U...

Страница 25: ...nt of Trailer Return Pressure View From Underneath Trailer Rear of Trailer Right Side of Trailer Left Side of Trailer Cross Drives 1 2 3 1 2 3 Switching Valve Restrictor Valves Adapter Block Check Val...

Страница 26: ...d View From Underneath Trailer Rear of Trailer Right Side of Trailer Left Side of Trailer Front of Trailer Return Pressure Cross Drives Control Valve Electric Switching Valve Check Valves Adapter Bloc...

Страница 27: ...19 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE 3 4 Drive Component Identification See RUNNING FLOOR II DX or DXE Parts Catalogs for additional details...

Страница 28: ...Loose floor bolts can severely damage floor slats If any bolts were loose bolt torques will need to be checked twice as often as recommended in the Maintenance section of this manual 3 6 Pre Trip Chec...

Страница 29: ...trailer floor should now be operating NOTE This ball valve controls On Off and is used as an emergency shut off CAUTION While unloading NEVER leave truck and trailer unattended WARNING Do not go under...

Страница 30: ...Off PTO Pump System or WALKING FLOOR unloader with the doors of the truck or trailer closed Catastrophic failure to the trailer as well as serious injury or death may occur 3 Inspect hydraulic hoses...

Страница 31: ...the area where the load is being discharged Burial loss of limb or life may occur 8 After unloading has been completed stop the floor with all slats in the forward position turn off the remote contro...

Страница 32: ...ter OFF EMS engaged and or Power Key not inserted RED blinking slowly Normal continuous signal link RED blinking irregularly ID codes don t match Frequency LED OFF Normal state RED Blinking irregularl...

Страница 33: ...Pump System or WALKING FLOOR unloader with the doors of the truck or trailer closed Catastrophic failure to the trailer as well as serious injury or death may occur 3 Inspect hydraulic hoses and quick...

Страница 34: ...or trailer while the system is in operation nor allow anyone to stand or move through the area where the load is being discharged Burial loss of limb or life may occur 8 After loading unloading has be...

Страница 35: ...ter OFF EMS engaged and or Power Key not inserted RED blinking slowly Normal continuous signal link RED blinking irregularly ID codes don t match Frequency LED OFF Normal state RED Blinking irregularl...

Страница 36: ...ote control is ready for use UNLOAD Push and release the Up button on the control The floor will continue to move until the Up button is pushed again LOAD Push and hold the Down button The floor will...

Страница 37: ...ump System or WALKING FLOOR unloader with the doors of the truck or trailer closed Catastrophic failure to the trailer as well as serious injury or death may occur 3 Inspect hydraulic hoses and quick...

Страница 38: ...em can be left hand LH or right hand RH drive B Push the red button in 1 and turn it a half turn counter clockwise 2 Release the red button and it will pop out See image below The floor will start to...

Страница 39: ...for hydraulic leaks Check the operating temperature No single component should be warmer than 140 F 60 C while the system is running Check and torque all floor bolts attaching the floor slats See Bol...

Страница 40: ...rel Clamp Bolts require Loctite 243 PN 24079 3 4 in HCS 20 mm HCS 4 per cylinder 125 ft lbs 170 N m Cylinder Rod End Bolts 5 8 in HCS 16 mm HCS 8 per cylinder 135 ft lbs 183 N m Check Valve Adapter Bl...

Страница 41: ...33 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE 4 4 Cross Drive Wear Component Diagram...

Страница 42: ...34 DOC06179 Rev B OWNER OPERATOR MANUAL RUNNING FLOOR II DX DXE 4 5 Flooring Wear Component Diagrams...

Страница 43: ...e Is it set between 2800 3000 PSI 193 207 bar 9 9 Oil Is the oil reservoir full 9 9 Power Take Off Is the PTO engaged 9 9 Ball Valve Is the ball valve that engages the drive unit On Off pulled fully c...

Страница 44: ...541 475 3802 Fax 541 475 2169 Email Sales KeithWalkingFloor com Canada Brantford ON Phone 519 756 9178 Email CanadaSales KeithWalkingFloor com M xico Guadalajara Jal Phone 52 333 616 5079 Email KMC_Me...

Отзывы: