8 KANE200
series
manual
ROTARY
DIAL
POSITIONS
TIME
Displays Time
DATE
Displays Date
CO
2
Displays calculated Carbon Dioxide values once O
2
values are
below 18%.
O
2
Displays Oxygen values in %.
T Nett
Displays the difference between flue and inlet / ambient
temperatures.
If the flue probe’s temperature sensor is broken or open circuit it
displays - - - -.
T Flue
Displays flue (or inlet) temperatures in
o
F
or
o
C .
If the flue probe’s temperature sensor is broken or open circuit it
displays - - - -.
EFF
Displays calculated efficiency when O
2
values are less than 18%
EFFn, EFFg or EFFc as selected by the user.
X AIR
Displays calculated excess air when O
2
values are less than 18%.
Loss
(KANE200 only)
Displays calculated losses when O
2
values are less than 18%
CO
(not KANE200)
Displays Carbon Monoxide values in PPM as CO in ppm
normalized ac COn
Display value in mg/m
3
as COm
in mg/m3 normalised as CO
Ħ
BAT
Displays estimated battery life.
If battery voltage falls below a pre-set limit, the display flashes
"LOW BAT." every 10 seconds. See above to change the batteries or
use the optional mains adaptor
Fuel
Displays boiler / furnace fuel selected