19
HALF RACK OPERATION MANUAL
BATTERY REPLACEMENT PROCEDURE
Do not operate the equipment during battery replacement procedure. To replace the batteries, follow the instructions below.
BATTERY REPLACEMENT
TOOLS & MATERIALS REQUIRED
#1 Phillips
Screwdriver
#3 Phillips
Screwdriver
5/64-inch (2 mm)
Ball-end Hex Driver
2
D Batteries
“Lo-bA”
= Batteries are low,
replace immediately.
NOTE: If batteries are dead
(depleted), the Power Display
remains blank.
BATTERY TYPE AND LOCATION
Two D Batteries, located inside
the Power Module (the tower with
Thumb Buttons).
Disconnect air supply and release all air from the Rack
Remove Thumb Buttons
1
2
Hold “-” Thumb Button until
Resistance window = “0”
or until “hiss” sound stops.
Outlet
Disconnect Air Supply
Release All Air
WARNING
High pressure air
can cause severe injury. Disconnect
Air Supply. Release all air from the
Rack before servicing equipment.
2 Thumb Button
Assemblies
(It is OK for the
Inner Spring and Plug
to remain inside the
housing)
x4 Set Screws
POWER MODULE
REAR
+
+
-
-
(continue on next page)