3.0 Adjust 1
st
Op and 2
nd
Op Roller X-Gap
Before adjusting the x-axis gap of the roller, you must disconnect the air supply to the unit.
With the air disconnected manually push the roller towards the chuck.
Loosen the lock nut while holding the piston in position with the provided spanner.
Tighten or loosen the lock nut on the thread to adjust the stroke length of the piston. This stroke
length will correlate with how close the roller ends up to the chuck.
For example, a longer stroke length (less thread visible behind the piston) will result in the roller
being closer to the chuck.
After adjusting the roller gap and before operating the Cannular it is vital that you check that the
roller does not make contact with the chuck.
To confirm this, disconnect the air supply to the unit.
Then manually push the roller towards the chuck (so that the piston is fully actuated) then spin the
roller with your hands to make sure it does not hit the chuck.