KL25164
–
Chuck Installation Manual
Page
2
of
12
Last Updated 21/12/2022 16:17 PM
All Fully Automatic Cannular Canning Machines
–
Single Lane are calibrated and fitted with a B64
Chuck. The reason being is that the B64 can ends have a wider tolerance range compared to
VISY/CDLE or Super Can ends. Meaning that you will save money in the long term with maintenance
costs being heavily reduced and a greater consistency of cans that are within specification as a result
of wider double seam tolerances.
If you have damaged your B64 chuck or intend to use VISY/CDLE Can ends then please use this guide
install a new chuck and calibrate the Single Lane Canning Line to achieve correct double seam
specification and a Hermetic Seal.
If you intend to use VISY/CDLE Can ends then you will need to install a VISY/CDLE Chuck (
1.0
Changing the Chuck
To remove the B64 chuck which the Single Lane Cannular is supplied with it is easiest to first remove
the front splash guard and the 1
st
Operation Roller to get easier access to the chuck.
1.2Disconnect Air Supply and Power
Before working on the Single Lane Cannular, it is a good idea to turn power off to the unit disconnect
the air supply into the unit for safety. This will also be necessary to manually move the 1
st
and 2
nd
Operation Actuation Arms to bring the machine into specification once you have swapped the chuck.
1.3Remove the Front Splash Guard
Undo the allen bolts which hold the splash guard in position on the frame and then remove the
splash guard