Kegel8 ULTRA Скачать руководство пользователя страница 27

Kegel8

®

 Ultra Operation Manual

27

Warranty

We provide a warranty to the original purchaser, that this product will 
be free from defects in the material, components and workmanship, for 
a period of 2 years from the date of purchase by the distributor. 
If the distributor is satisfi ed that the product is defective, the user may 
return the unit directly to Savantini Limited. All returns must be au-
thorised and the warranty does not extend to any misuse or abuse such 
as drop ping or immersing the unit in water or other liquid substance 
or tampering with the unit or normal wear and tear. Any evidence of 
tampering will nullify this warranty. 

Customer Service and Distribution:

Please contact your distributor for any customer service enquiries, 
including the warranty returns. Your invoice of purchase and/or the 
rear cover of this manual should state the name and the contact details 
of your distributor.
For assistance, if needed, in setting up, using or maintaining the unit, 
or report unexpected operation or events, please visit the distributor’s 
website for further details: www.kegel8.co.uk

Distributed by:  

Savantini Ltd.

  

 

 

Savantini House, Foster Street

 

 

 

Stoneferry Road, Hull

 

 

 

HU8 8BT, UK

 

 

 

Fax: +44(0) 1482 873570

 

 

 

Email:  [email protected]

 

 

 

Web: www.kegel8.co.uk

 

 

 

Helpline: 

 

 

 

+ 44(0) 1482 496 932

 

 

 

 

This product is manufactured by Verity Medical Ltd., in 

 

 

compliance with the European Union Medical Device  

 

 

Directive MDD93/42/EEC under the supervision of  

 

 

LRQA Ltd., (Lloyd’s Register Quality Assurance Ltd),  

 

 

Notifi ed Body number 0088. Verity Medical Ltd., is   

 

 

certifi ed by LRQA Ltd., to the following Quality 

 

 

Standards: ISO 9001:2008, ISO13485:2003.

Содержание ULTRA

Страница 1: ...Kegel8 Ultra Operation Manual 1...

Страница 2: ...r when you report a technical fault or claim a warranty return Manufacturer s serial number of the unit Present it together with LOT number when you report a technical fault or claim a warranty return...

Страница 3: ...arger Never connect the Kegel8 Ultra directly to a battery charger or to any other mains powered equipment We advise not to use Ni Cad rechargeable batteries Patient Electrodes are for single patient...

Страница 4: ...Instructions 9 Setting up your Customized Programme 11 Lock Button 12 Continence Treatment Programmes 13 Electrode Types Tips 19 Care Maintenance Accessories and Disposal 20 Indications for use 21 Sp...

Страница 5: ...l8 Ultra is a dual channel device combining several treatment programmes into one unit Neuromuscular Stimulation is increasingly understood by Therapists and Doctors There is a better understanding of...

Страница 6: ...lly dangerous equipment Do not place electrodes Over carotid sinus nerves Over larynx or trachea Inside mouth Over the area of the heart unless so advised by your Doctor On your facial area unless und...

Страница 7: ...me SET button Reduces the intensity mA to zero and pauses the programme if a programme is running and moves the phase one step forward Displays the menu for programmes PC1 PC3 and allows the parameter...

Страница 8: ...Time of current phase Number of phases Phase mode Work Rest Alt Cont Mod 3 Hz 250 uS PC1 5 WK Min 4SEC Programme Total programme time adds cumulatively as time added to phases Set Work Rest Ramp Delay...

Страница 9: ...e to each of the pin connectors at the end of the lead wire The red and black polarity are good either way Some probes have a long wire built in with the direct socket to the unit 5 Make sure the Vagi...

Страница 10: ...eturning to storage in the plastic bag Low Battery Indicator When the battery power is low the low battery indicator will appear on the screen shown in the diagram on page 7 When the battery indicator...

Страница 11: ...est seconds between 2 and 99 seconds 9 Press CH A RP will appear and ash press CH B to set the ramp seconds between 0 1 and 9 9 seconds 10 Press CH A AL or SY will appear and ash press CH B to select...

Страница 12: ...up correctly 2 Remove the battery cover and using a thin rod gently press on the lock button as shown in the diagram on page 6 until you hear a double beep The unit is now locked and cannot be altered...

Страница 13: ...on S 150 Ramp up time secs 1 0 Ramp down time secs 0 Work time secs Cont Rest time secs 0 Alternating Synchronous Overall time 20 min Programme P02 Urge Incontinence Phase 1 Phase 2 Phase 3 Phase 4 Ph...

Страница 14: ...p time secs 1 0 Ramp down time secs 0 Work time secs 6 Rest time secs 15 Alternating Synchronous Overall time 20 min Programme P04 Stress Incontinence 2 Phase 1 Phase 2 Phase 3 Phase 4 Phase 5 Phase t...

Страница 15: ...time secs 1 0 Ramp down time secs 0 Work time secs 5 Rest time secs 5 Alternating Synchronous Overall time 20 min Programme P06 Frequency Urge 2 Phase 1 Phase 2 Phase 3 Phase 4 Phase 5 Phase time min...

Страница 16: ...ously with no rest period It is used in some countries where they have found continuous stimulation can work e ectively Programme P08 Lack of Sensitivity Phase 1 Phase 2 Phase 3 Phase 4 Phase 5 Phase...

Страница 17: ...Ramp up time secs 0 8 0 8 0 8 0 6 0 8 Ramp down time secs 0 0 0 0 0 Work time secs 5 5 5 5 5 Rest time secs 5 5 5 6 7 Alternating Synchronous Overall time 45 min Programme P10 Building Up Endurance P...

Страница 18: ...uration S 220 Ramp up time secs 1 2 Ramp down time secs 1 2 Work time secs 6 Rest time secs 10 Alternating Synchronous Overall time 20 min This programme helps to relax the pelvic muscle It may be use...

Страница 19: ...y cleansing the skin with a swab impregnated with alcohol Clip away hairy skin using scissors don t use a razor to remove the hair The electrodes conductive material is water based If it becomes satur...

Страница 20: ...ically for any discharge from the battery Remove battery completely from unit if not in use for any extended period of time typically one week Low battery indicator of 6 9 volts shown on LCD display W...

Страница 21: ...they drop onto the oor debris will adhere to conductive gel rendering the electrodes ine ective Electrode life can be considerably reduced by The type and condition of the skin Deep seated moisturiser...

Страница 22: ...accuracy 7 Time duration of the treatment selectable 1 minute to 90 minutes 8 Low Battery Indicator If the battery goes below 6 9 volts 0 2 volts the battery symbol will ash on o once every second 9 O...

Страница 23: ...RF emissions interference to be immune from e ects of interference produced by other equipment operating in their vicinity and damage due to electrostatic discharge all when operating in a typical do...

Страница 24: ...Kegel8 Ultra Operation Manual 24...

Страница 25: ...Kegel8 Ultra Operation Manual 25...

Страница 26: ...commend that the next best position is to sit down and lean back slightly 5 If you think the probe itself is not working wash it and hold it using your rst nger and thumb or elbow crook to make a conn...

Страница 27: ...for any customer service enquiries including the warranty returns Your invoice of purchase and or the rear cover of this manual should state the name and the contact details of your distributor For a...

Страница 28: ...Kegel8 Ultra Operation Manual 28 Clinical References Please contact us for any clinical referencies of Kegel8 enquiries kegel8 com...

Страница 29: ...Kegel8 Ultra Operation Manual 29 Notes...

Страница 30: ...Kegel8 Ultra Operation Manual 30...

Страница 31: ...Kegel8 Ultra Operation Manual 31...

Страница 32: ...A Document revision info Kegel8 Ultra manual English OPH200 OM EN13 23 01 2019 Savantini Ltd Savantini House Foster Street Stoneferry Road Hull HU8 8BT England Any queries should be addressed to Helpl...