USER MANUAL - operation
Slim Jim User manual
page 15
Change settings in the Barista menu
You have to leave the operational window of the controller and choose the correct parameter-set to
change individual settings.
operational
window
touch
menu window
touch
settings window
touch
enter barista
password window
use up and down
to change the
value of the
underlined digit,
use previous and
next to change
digit
use arrows to construct the password (33333)
touch
barista menu
window
choose a sub-
menu or exit to the
operational
window
Sub-menu TEMPERATURE SETTING
In the sub-menu temperature setting you can consecutively adjust the following:
parameter
range
factory increment
unit
remark
display
°C, °F
°C
setpoint group 1
80.0 .. 99.9°C
176 .. 212°F
93.0°C
199.4°F
0.1
°C or °F
setpoint group 2
setpoint group 3
In a Duette there is no group 3.
setpoint steam
110 .. 130°C
230 .. 266°F
125°C
257°F
1
cup heater
0 .. 100
0
1
%
OFF at “NO HEAT” and “ECO-all”
show temp. at
ECO
no, yes
no*
When “yes” the digit displays will
show a temperature at ECO.
When installed and in use, the cup-heater will be active the set percentage of each consecutive period
of 100 seconds.
* The 3-digit displays
will show “ECO” instead of a temperature when the corresponding boiler is at
ECO. This can be changed to keep showing the actual temperature.
GROUP 1
93.4
GROUP 2
45.6
GROUP 3
93.2
STEAM
124.6
MENU
STAND
BY
EXTERNAL
SENSOR
CLEAN
PROGRAM
SETTINGS
13:57
FACTORY
LEVEL
TECHNIC
LEVEL
MANAGER
LEVEL
BARISTA
LEVEL
EXIT
BARISTA PASSWORD:
00000
ENTER
TEMP.
SETTING
VOLUME
SETTING
TIME
DATE
TIMED
ON/OFF
EXIT