Initial Start Up
Section 2
S4 Application Manual
Page 6
2.2 Verifying motor operation
Connect the control terminal strip as indicated in the figure below.
Turn the supply voltage to the amplifier
on. The display on the amplifier will
show actual motor speed. Close one of
the jog switches and the motor should
begin to turn. The display should
indicate an actual speed of about 100-
rpm. Open the jog switch and the
motor should stop. Close the other jog
switch and the motor should run in the
opposite direction. If the motor runs in
both directions without any errors, then
the system has been properly installed
and is ready to be set up for the
application.
In the event the motor does not turn in
one or both directions, please refer to
the table on the following page as a
troubleshooting guide.