Application Examples
S4 Application Manual Section 3
Page 11
•
The reference point search only happens once after the supply voltage to the drive
is first turned on. After that the drive will make only position moves when a signal is
given to terminal 2.
•
Terminals 6 and 7 are binary coded for positions 0 through 3. The position selection
signals must be maintained at least until after the start move pulse is given on
terminal 2.
•
Terminal 8 and 9 are digital outputs.
•
All signals with a vertical arrow are edge triggered and must be brought low before
the drive will accept another signal at that terminal.
3.2.4 Single axis positioning control wiring