Regulator Adjustment
Section 4
S4 Application Manual
Page 36
4.3.8 Graph
I - position is increased further. Position deviation decreases but creep remains. Solution
is to increase I and P.
Actual speed
100 rpm / div
P – Speed (CS.00)
400
Set speed
100 rpm / div
I – Speed (CS.01)
150
Horizontal
100 mSec /div
P – Position (Pd.02)
250
Angular deviation
2° mSec / div
4.3.9 Graph
If the I-speed and the P-position gains are set too high, high frequency torque oscillations
will occur. This can sound like a buzzing noise coming from the motor. Once the
oscillation starts, reduce the gains until it stops.
Actual speed
100 rpm / div
P – Speed (CS.00)
400
Set speed
100 rpm / div
I – Speed (CS.01)
600
Horizontal
100 mSec /div
P – Position (Pd.02)
500
Torque
35 Ib in / div
Содержание COMBIVERT S4