Application Examples
S4 Application Manual Section 3
Page 19
3.3 Single axis index to length
3.3.1 Application
definition
•
The system must index incrementally in one direction relative to the previous stopping
point.
•
The system must have the capability to enter a search mode at the end of each index
to establish positive stopping point based on registration mark.
•
The system must be able to search to the registration mark on demand.
•
Manual mode of operation must accommodate jogging of the system.
3.3.2 System
Layout
Web index with registration marks
Conveyor index without registration marks