4.12 Busbars for the supply voltages
The supply unit supplies the power to the axis controllers separately for the control
section and DC link. The control section receives its 24 V supply from the switched-
mode power supply in the supply unit via the upper busbar (+24 V DC and GND,
see Figure 4.13). The DC link supply comes from an unregulated DC voltage and is
connected to the axis controllers via the lower busbar (DC Link +/-).
Step
Action
Comment
1.
Make sure the supply unit is arranged in a line with all axis
controllers and they are together in a row.
See installation instructions
2.
Use the busbar elements supplied for the control supply for the
axis controllers. Connect together all (+24 V DC) connections
and all (GND) connections.
The busbar elements are as long
as the related device is wide.
3.
Use the busbar elements supplied for the DC link supply for the
axis controllers. Connect together all (DC Link+) connections and
all (DC Link-) connections.
The busbar elements are as long
as the related device is wide.
CAUTION!
Damage to the drive system due to incorrect wiring!
Carelessness may result in damage to the device.
x
Use the connection elements supplied (busbars) for the electrical coupling of the devices.
x
Make sure that all connections have good contact and are sufficiently secure (2.1 Nm) that
they cannot come loose.
NOTE!
On the usage of other connection elements (busbars), KEBA does provide any
guarantee for stable, reliable operation.
4.11 24 V DC output
Along with the busbars, the 24 V DC output voltage from the switched-mode power
supply is also available on connector X2. Here it is to be noted that the sum of the power
required on the busbars and the connector X2 is not allowed to exceed the max. output
power of 470 W.
4.11.1 Connector X2 specification
Des.
Term.
Specification
Connection
X2
+24 V
x
24 VDC
x
Connection cross-section:
6 mm
2
max.
X2
+24 V
GND
GND
For layout see Figure 4.10 and Figure 4.11
Table 4.10
Specification 24 V DC output X2 BG1 and BG2
NOTE:
The same switched-mode power supply is installed in supply unit BG1 and in
BG2. The technical data are therefore identical.