24
1 Electrical installation
Operation Manual Supply Unit SO CM-P BG1+2
ID no.: 1400.201B.5-00 Date: 02/2020
Electrical installation
Abbreviation
Designation
Details
24 V DC / GND
24 V control supply output via busbars
DC Link +/-
DC link supply output via busbars
X1
Connection for braking resistor
X2
24 V control supply output via terminals
X3
Cross-communication output (XC out)
X5
Relay contact (RO02), programmable
X6
Relay contact (RO01)
Digital outputs (TPO1, TPO2)
X7
Switched-mode power supply mains input
(L1, L2 / 2 x 400 V AC)
See Chapter 4.8
X8
DC link supply mains input
(L1, L2, L3 / 3 x 230/400/480 V AC)
See Chapter 4.6
PE
Protective earth conductor connection
See Chapter 4.4
Shield connection, control cable
Table 4.1
Key to the ServoOne CM-P supply unit layout
4.3 Overview of the connections
The following shows the layout of ServoOne CM-P supply unit with the corresponding
positions of connectors and terminals. For improved clarity we have added an
abbreviation to the designation for the connectors and terminals.
X7
X1
X2
X3
24 V DC / GND
DC Link +/-
X6
X5
X8
PE
Figure 4.3
Layout, ServoOne CM-P supply unit
Содержание ServoOne CM-P BG1