Mechanical installation
Operation Manual Supply Unit SO CM-P BG1+2
ID no.: 1400.201B.5-00 Date: 02/2020
Mechanical installation
3.3 Cooling the devices
Cooling air must be able to flow through the device without restriction. On installation in
switch cabinets with convection (= heat loss is dissipated to the outside via the cabinet
walls), always fit an internal fan. If a temperature cut-out occurs, the cooling conditions
must be improved.
Figure 3.3
Cooling air flows unhindered through the device
3.4 Installation of the devices for wall mounting
Step
Action
Comment
1.
Arrange the supply unit on the backing plate as per
Please also provide enough space to the left of the supply
unit for the MotionOne CM controller.
Align all devices in a line along the top edge of the devices.
This action is necessary to be able to
couple the DC link using the pre-assem-
bled busbars.
2.
Mark out the position of the tapped holes on the backing
plate.
Drill holes in the backing plate and cut a thread for each
fixing screw in the backing plate.
Pay attention to the bending radius of the
connection cables!
For hole spacing and dimensional draw-
ings, see Table 3.1 and Figure 3.4.
3.
Mount the ServoOne CM-P supply unit vertically and butt
mounted in a row with the axis controllers on the backing
plate.
The contact surface must be bare metal
and conductive.
Continue with the electrical installation in chapter 4.