5
Connections and wiring
5.1
Pin assignment
Fig.5-1:
Position of the connection
1
... 0V | 24 V: Power supply operating panel
(24 V DC, 2-pole
2
... Digital inputs (16), for the connection of
external switching elements such as
toggle switches etc.
3
... EXT0: External interface, exclusively for
the connection of an RFID module.
4
... SI0: RS-485-A interface
5
... VCC_USB: USB module 12V
DC exclusively for the KEBA USB mod-
ules
6
... Adj.: Adjust equalizer (setting for trans-
mission range), only for operating pan-
els with PL.
7
... Graphics: Graphics interface for the
control
The interface cables that can be ordered from KEBA are in the
"Ordering information" on page 19
for further information.
5.2
Power supply operating panel (0V | 24V)
The operating panel is supplied by 24 V DC.
WARNING!
Please observe the safety-relevant information in the
structions for personal safety" on page 11
Connections and wiring
OP 350/C-1100
© KEBA 2009