5.2.1
Connection diagram
Fig.5-2:
24 V DC connection diagram
5.2.2
Plug specification
Connection terminals: 2-pin male connectors (Weidmüller SL-SMT 5.08). The
necessary female connectors are not included in the scope of delivery of KE-
BA.
Cross section according to manufacturer specifications:
Connectable conductor
Cross-section
Clamping range min.
0.13 mm²
Clamping range max.
3.31 mm²
AWG, min.
26
AWG, max.
12
single-wire, min. H05(07) V-U
0.2 mm²
single-wire, max. H05(07) V-U
2.5 mm²
finely-stranded, min. H05(07) V-K
0.2 mm²
finely-stranded, max. H05(07) V-U
2.5 mm²
with wire sleeves according to DIN 46 228/1.
min.
0.2 mm²
with wire sleeves according to DIN 46 228/1.
max.
2.5 mm²
with AEH with collar DIN 46 228/4 min.
0.2 mm²
with AEH with collar DIN 46 228/4 max.
2.5 mm²
chapter 3.6.3.2 "Connector" on page 20
5.2.3
Cable specification
Cable type: Unshielded cable
Cross-section
The actual permissible wire cross-section is specified by the electrical condi-
tions of the connected equipment an the female connectors used:
Operating panel
Connections and wiring
© KEBA 2009
Project engineering manual V2.00
25
Содержание Kemro OP 350/C-1100