background image

E10

Directives, standards and regulations

V1.00

29

© KEBA 2023

14

Directives, standards and regulations

2014/35/EU

Low-Voltage Directive

2014/30/EU

Electromagnetic Compatibility Directive

2011/65/EU

Directive on the restriction of the use of cer-
tain hazardous substances (RoHS)

2012/19/EU

Directive for waste electrical and electronic
equipment (WEEE)

Electromagnetic compatibility

EN 61000-3-2

Electromagnetic compatibility (EMC) – Part
3-2: Limit values - limit values for harmonic
current emissions (equipment input current ≤
16 A per conductor)

EN 61000-3-3

Electromagnetic compatibility (EMC) – Part
3-3: Limit values - Limitation of voltage
changes, voltage fluctuations and flicker in
public low-power supply systems, for equip-
ment with rated current ≤ 16 A per conductor
and not subject to conditional connection

EN 61326-1

Electrical equipment for measurement, con-
trol and laboratory use - EMC requirements -
Part 1: General requirements (IEC
61326-1:2012)

EN 55011

Industrial, scientific and medical equipment -
Radio-frequency disturbance characteristics -
Limits and methods of measurement

14.1

EU Directives and Standards

2014/35/EU

Low-voltage Directive

2014/30/EU

Electromagnetic Compatibility Directive

2011/65/EU

Directive on the restriction of the use of cer-
tain hazardous substances (RoHS)

2012/19/EU

Directive for waste electrical and electronic
equipment (WEEE)

Содержание KeContact E10

Страница 1: ...KeContact E10 Energy meter Installation manual V 1 00 Original instructions...

Страница 2: ...o further technical developments Details presented may be subject to correction All rights reserved KEBA Energy Automation GmbH Reindlstra e 51 4040 Linz Austria www keba com emobility 43 732 7090 0 4...

Страница 3: ...ts 13 5 1 LED displays 13 5 2 Reset button 14 6 Mounting and installation instructions 15 6 1 Space requirement 15 6 2 Mounting the device 15 7 Connections and wiring 16 7 1 Connection overview 16 7 2...

Страница 4: ...update via web server 24 11 2 Troubleshooting 24 12 Disposal 26 13 Technical data 27 13 1 General 27 13 2 Power supply 27 13 3 Ambient conditions 27 13 4 Interfaces 27 13 5 Dimensions weight 27 13 6 C...

Страница 5: ...in death or se rious bodily injury if the corresponding precautions are not taken WARNING indicates a potentially hazardous situation which can result in death or seri ous bodily injury if the corres...

Страница 6: ...plies the elec trical measured values at the terminal The data collected by the device may deviate from the data of the main energy meter Information This device is NOT an active electrical energy met...

Страница 7: ...It is to be retained over the entire life cycle of the product and should be forwarded to any subsequent owners or users of the product The instructions contained in this manual must be followed prec...

Страница 8: ...ermitted housings or electrical distribution boards downstream of the PSC meter so that the connections for the phase conductor and neutral conductor are located behind a cover or contact protection C...

Страница 9: ...of wire etc get inside Never clean the device with aggressive solvents and cleaning agents abrasive materials spray water garden hose high pressure cleaner etc or excessive pressure Caution Damage in...

Страница 10: ...of delivery The following parts are included in the scope of delivery Description Number KC E10 1x 4 pin connection plug 1x 6 pin connection plug 1x Split core current transformer 63 A KC E10 1P 63A...

Страница 11: ...sible power draw sub tracts the total consumption and regulates the charging power The mea sured values are used to calculate the available capacity and the charging current is distributed to the vehi...

Страница 12: ...code 3 Production date year week 4 Manufacturer s address 5 Technical data 6 CE conformity marking 7 Electrician symbol according to IEC 60417 6182 8 Reference to safety notes accord ing to ISO 7000...

Страница 13: ...reen slow The device is in software update mode and the web inter face is active Flashing orange 2x Confirmation for resetting to factory settings Red A critical error has occurred Flashing red fast A...

Страница 14: ...s located on the front of the device and is required for the following purposes Restarting the device see 8 1 Restarting the device Resetting the device to factory settings see 8 2 Resetting the devic...

Страница 15: ...es to the surround ings Fig 6 5 Space requirement specified in mm 6 2 Mounting the device The KC E10 is intended for installation on a horizontal mounting rail in a control cabinet To mount the device...

Страница 16: ...3 Energy meter of the power supply company PSC 4 Post meter fuses 5 Split core current transformer 6 KC E10 7 16 A Type B fuses 8 Consumer In 1 phase operation the split core current transformers and...

Страница 17: ...ke sure that the phases are each correctly assigned Otherwise the device will return false measured values To connect the split core current transformers proceed as follows 1 Connect the connection ca...

Страница 18: ...3 and neutral conduc tor N to the terminals of the 4 pin plug scope of delivery 2 Connect the connection plug to the energy meter The power supply is connected Information Make sure that the phases ph...

Страница 19: ...9 KEBA 2023 The measurement data can be read out using the Modbus protocol via the Ethernet interface The device Modbus TCP slave can be reached under the port 502 by default The Unit ID corresponds t...

Страница 20: ...ter 61615 0xF0AF 8 2 Resetting the device to factory settings To reset the device to factory settings proceed as follows 1 Press the reset button with a pointed object briefly 1x approx 0 5 sec onds 2...

Страница 21: ...1 Measuring interval register 256 The measuring interval can be set using Modbus register 256 0x0100 The following values can be set Value Description 1 100 ms 2 200 ms default 3 500 ms 4 1000 ms 9 2...

Страница 22: ...ead only flag is set no other configuration can be per formed All Modbus configuration registers only allow read access function code 0x3 Write access leads to Modbus exception code 0x03 Illegal Data...

Страница 23: ...ed active energy Total inductive reactive energy Total capacitive reactive energy Total imported apparent energy Total exported apparent energy Power factor Frequency The following measured values are...

Страница 24: ...ister The status LED flashes green 2 Open the web server by entering the IP address of the device in a web browser on the PC The device must be in bootloader mode to do so 3 Select the update file usi...

Страница 25: ...o the network connection The KC E10 is not in the same lo cal network Connect the KC E10 with the same router switch The device sup plies unrealistic measured val ues Incorrect connections or faulty c...

Страница 26: ...l with the crossed out waste container means that electrical and electronic devices including their accessories must not be disposed of in the household garbage The materials are recyclable in accorda...

Страница 27: ...accordance with EN 60664 Cable cross section 0 2 2 5 mm2 13 3 Ambient conditions Use Indoor Access limitations at set up location Limited access control cabinet Installation stationary On a top hat r...

Страница 28: ...e cross section 0 2 mm2 Measurement category CAT III Ambient conditions Use Indoor Access limitations at set up location Limited access control cabinet Operating temperature 20 C to 70 C Storage tempe...

Страница 29: ...ity EMC Part 3 3 Limit values Limitation of voltage changes voltage fluctuations and flicker in public low power supply systems for equip ment with rated current 16 A per conductor and not subject to...

Страница 30: ...E10 Declaration of conformity V1 00 30 KEBA 2023 15 Declaration of conformity...

Страница 31: ...E10 Declaration of conformity V1 00 31 KEBA 2023...

Страница 32: ...ing 25 EU Directives and Standards 29 F Factory setting 20 I Installation 10 L LED Network 13 Service interface 13 Status 13 M Measuring interval 21 N Network configuration 21 R Read only flag 22 Rest...

Страница 33: ......

Страница 34: ...KEBA Energy Automation GmbH Reindlstra e 51 4040 Linz Austria www keba com...

Отзывы: