DANGERS, WARNINGS, CAUTIONS

Danger

 

Failure to observe the following procedures may result in serious personal injury.

•   Not for use in explosive or hazardous locations.  

•   Contains built-in lithium polymer battery.  Do not incinerate or dispose of in fire.  Do not disassemble, alter, or re-construct.

  Warning

 Failure to observe the following procedures could damage the instrument.

•   Read the manual before operation. 

•   Do not store in temperatures outside -20°C to 60°C (-13°F to 140°F)

•   Do not immerse in liquids.

•   Condensation may damage your instrument.

•   Substitution of components may impair the accuracy of the instrument.  Repair should be done by authorized service 

personnel only.

 Caution   

•   The battery in this instrument has limited shelf-life, even if never used.

•   A non-condensing environment is required for proper measurements.

•   Do not charge battery outside the range of 0°C to 40°C (32°F to 104°F)

 Battery run-time may be reduced when operating at temperatures lower than 0°C (32°F).

•   It is recommended that the SE-400 Series is charged for approximately 4 hours before first use.

•   The 3M SE-400 Series Sound Level Meter may not be sufficient to carry out a full risk assessment of workers exposed to 

hazardous noise levels.

 Intended Use

The SE-400 Series is intended to measure sound pressure levels in air and provide local sound and noise detection 

measurements.  It is fitted with 12 keys for powering on/off, viewing and/or running/stopping measurements, navigating and 

setting parameters (See Figure 1 for more information).   For suitability and proper use follow local regulations and refer to all 

information supplied.  For more information contact a safety professional/3M representative (Local Contact Details).

  SE-400 SERIES DISPLAY AND KEYPAD 

Figure 1

A.  Softkeys:  four softkeys used as additional menu options with specific screens.

B.  Backlight Key:  used to illuminate the background of the display screen.

C.  Up Arrow Key:  used to toggle through menu/setup options and scrolls through the 

      values on the measurement screen.

D.  Left Arrow Key:  used to navigate through menus and setup parameters.

E.  Run/Stop Key:  used to run and stop a logged session.

F.  Right Arrow Key:  used to navigate through menus and setup parameters.

G.  Enter Key:  used to select menus and confirm setup parameter changes.

H. Down Arrow Key:  used to toggle through menu/setup options and scrolls through the   

    values on the measurement screen. 

I.  On/Off/Esc Key:  used to power on, power off and/or escape or move back one screen.

J.  Windscreen:  used to reduce noise effects from wind with minimal effects on the readings.

A

B

C

D

E
F

G

 H

 I

J

 

  

 

 

 

  

 

 

   GETTING STARTED

Attaching the Preamp

The SE-400 Series, model SE-401 is equipped with a removable preamp and is shipped unattached to the SLM.

1.  Place the preamp connector over the mating connector at the top of the instrument.  Gently press down while 

     rotating the preamp ring until the preamp connector drops into place.  

2.  Rotate the preamp ring until secure.

Charging

The SE-400 Series is charged using the supplied USB charger or personal computer’s USB port.  A fully depleted 

battery will require approximately 8 hours to fully charge when using the external battery charger.  

Status of battery icon:

 When charging, the battery indicator will scroll, shading in the indicator. When the 

battery is fully charged, the battery indicator will stop scrolling. 

Powering On/Off

   1.  To turn on the SE-400 Series, press the           key until the start screen appears.
   2.  To turn off the SE-400 Series,  ensure the meter is stopped.  Press and hold the            key until the 
         measurement screen disappears.   

Calibrating

It is advisable to perform a field calibration before taking measurements to ensure your measurements are 

accurate in the current environment.

             

1.   Ensure the SE-400 Series is turned 

On

, stopped, and not logging.

2.   Attach the calibrator and calibrator adapter to the SE-400 Series.  Set the calibrator to 1000 Hz and 114 dB 
     (if it is selectable).  
3.  Turn 

On

 the calibrator.

4.  From the measurement screen, press the corresponding softkey from the              menu.     
5.  Press the 

CAL

 softkey or select 

Calibration

.   (See Figure 2-A).

6.  In the calibration screen, press CAL softkey or press            key (See Figure 2-B).
7.  Press the corresponding            softkeys to adjust the measurement to 114.0 dB  (See Figure 2-C).  
8.  Press the            key to save the changes or escape to abort.  
9.  Press the            key twice to return to the main measurement screen.  

     

 Figure 2-A 

 

 

 

 Figure 2-B   

 

           Figure 2-C

SE-400 QS_Final_global copy.indd   1

11/16/2011   5:02:15 PM