background image

SAFETY
PRECAUTIONS

THIS SYMBOL WARNS YOU THAT SERIOUS BURNS
OR OTHER INJURIES MAY RESULT IF SAFETY
INSTRUCTIONS ARE NOT FOLLOWED.

This service manual should be retained in a safe
place for future reference.  The installation of your
new Pasta System must conform to local codes
and with the current National Electrical Codes and
regulations as applicable.

Your ventilation hood, when installed, must
conform to the current standards.

No frame or restriction shall be constructed around
the Custom Pasta System that will restrict air
movement into the Pasta System or prevent
proper ventilation.

You must maintain this appliance free and clear 
from combustibles.

Adequate clearance for servicing and proper
operation must be maintained. Your pasta system
is designed to be serviced from the front.

Keating Custom Pasta

Systems are not intended

for household use.  Installation in household voids
warranty.

ALWAYS instruct new employees on proper pasta
system operation.

A Custom Pasta System

should be operated 

ONLY by properly trained personnel.

ALWAYS turn pasta system off each night.

ALWAYS turn pasta system off at customer power
panel before servicing.

NEVER leave a pasta system unattended during 
operation.

NEVER move a pasta system when full of hot 
water.

NEVER introduce objects or liquids into pasta 
system, while operational, which are not designed
or made for cooking.

THIS CUSTOM PASTA

SYSTEM MAY NOT BE 

ALTERED, MODIFIED OR CHANGED IN ANY
WAY. 

IF THE EQUIPMENT IS NOT

INSTALLED, OPERATED AND
MAINTAINED IN ACCORDANCE
WITH THE ABOVE,
CONCENTRATIONS OF CARBON
MONOXIDE IN EXCESS OF THE
ESTABLISHED LIMITS COULD BE
PRESENT IN THE KITCHEN
ENVIRONMENT.

ALL PERSONNEL IN THE WORK PLACE WHO MAY
BE SUBJECT TO ANY EXPOSURE OF CARBON
MONOXIDE MUST

BE WARNED OF SUCH

POSSIBLE EXPOSURE. THIS WARNING SHOULD
BE CONVEYED IN A MANNER SO THAT IT IS
CLEARLY UNDERSTOOD BY THE EMPLOYEE, AND
THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE
OR SHE UNDERSTANDS THE CORRECT METHOD
OF OPERATION OF THE EQUIPMENT AND THAT A
RISK OF EXPOSURE EXISTS IF THE EQUIPMENT
IS OPERATED IMPROPERLY.

IF NOT INSTALLED, OPERATED AND MAINTAINED
IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, THIS PRODUCT COULD EXPOSE
YOU TO SUBSTANCES IN FUEL OR IN FUEL
COMBUSTION WHICH CAN CAUSE DEATH OR
SERIOUS ILLNESS AND WHICH ARE KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER,
BIRTH DEFECTS OR OTHER REPRODUCTIVE
HARM.

WARNING

Improper installation
can cause damage,
injury or death.

3

Содержание 24763

Страница 1: ...KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Part 024763 Electric Pasta 0709 7 09 CUSTOM PASTA SYSTEM ELECTRIC SERVICE MANUAL...

Страница 2: ...nufacturer of all warrant and liability Keating of Chicago Inc manufacturer reserves the right to change specifications at any time IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE C...

Страница 3: ...Calibration 9 10 Auto Fill Safety Shut Off 10 Sensor Tube Cleaning 10 SECTION V SERVICE DIAGNOSIS Auto Fill System 11 Cooker Heating Section 11 Troubleshooting Charts 12 13 SECTION VI PARTS LIST Orde...

Страница 4: ...ic timers Low water safety shutoff 1 full port front drain valve on 14 11 4 for 18 and larger High temperature limit control with manual reset Patented accurate temperature control system 2 F Ideal 35...

Страница 5: ...power panel before servicing NEVER leave a pasta system unattended during operation NEVER move a pasta system when full of hot water NEVER introduce objects or liquids into pasta system while operati...

Страница 6: ...en file a claim with the carrier since such damage is the carrier s responsibility By following these instructions carefully we guarantee our full support of your claims to protect you against loss fr...

Страница 7: ...device or its associated piping to limit the appliance movement Connectors must comply with ANSI Z21 69 CAN1 CAN CGA 6 16 latest edition for connectors for movable gas appliances Quick disconnect devi...

Страница 8: ...difference between the two thermostats Having less than a twenty degree difference will increase the possibility of a boil over and cause the pasta cooker to short cycle The recommended starting tempe...

Страница 9: ...t Lift Model 1 Fill Pasta System as described on page 6 Filling 2 Set primary left thermostat to 212 F 100 C and secondary right thermostat to 190 F 87 8 C 3 Fill basket s to proper level and place on...

Страница 10: ...turn ON and the display will now be indicating OR The BEEPER will BEEP 4 times NOTE If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more...

Страница 11: ...any maintenance problem is directly or indirectly related to cleanliness NOTE Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty NOTE Use of sod...

Страница 12: ...cleaning Control of the water level is fully automatic with the auto fill system The water level is controlled by two circuit boards and two sensors The sensors are located in the tube on the right s...

Страница 13: ...it The potentionmeter adjusts the sensitivity of the probe Adjusting this sensor will not increase the depth of the water Improper adjustments can effect the operation of the cooker and cause damage...

Страница 14: ...not minutes or seconds 1 Reset the timer see pages 8 9 Water leaking in the rear of the pasta cooker 1 Replace fill hose Part 037390 sold per foot Breakers continue to trip 1 Ensure all wires to the c...

Страница 15: ...echanism does not operate a Connections are loose or timer is faulty b Motor limit switch is faulty c Lift motor is faulty d Actuator is faulty e Control circuit fuse has blown f Relay is faulty a Tig...

Страница 16: ...1 Custom Pasta System Electric Control Panel 1 2 3 2 4 5 6 6 7 7 ORDERING PARTS Parts may be ordered by part number by calling Keating at 1 800 KEATING or your local servce company You may also order...

Страница 17: ...SMALL 002565 CIRCUIT BREAKER 40AMP 1P 012129 4 6 6 4 FUSE 300V 3AMP 004334 2 2 2 2 CONTACTOR 110V 3P 50AMP 011225 3 3 3 2 CONTRACTOR 110V 4P 40AMP 005597 1 TRANSFORMER STEPDOWN 004376 1 1 1 1 220 110V...

Страница 18: ...16 VII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS 2...

Страница 19: ...14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM 17...

Страница 20: ...18 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 21: ...19 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...

Страница 22: ...20 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 23: ...21 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Страница 24: ...22 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Страница 25: ...OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installatio...

Страница 26: ...______________ INVOICE NUMBER __________________________ SERIAL NUMBER ______________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ____________________________________ TOP SIDE COOKER HOT PLATE...

Отзывы: