background image

9

When the countdown has reached "00:00" the relay
output contacts will open, the display will flash, and the
audible alarm will sound. To cancel the audible alarm,
press any button.

C. PAUSE FEATURE

To pause a cycle in progress, press any button. The
relay output contacts will open, the display will flash,
and the countdown will pause. To resume the
countdown, press any button. The display will resume
the normal countdown and the relay output contacts will
close.

D. CANCELING A CYCLE

To cancel a cycle in progress press and hold any button
for  approximately two seconds. The relay output
contacts will open and the display will show the time
setting  for the cook time last used.

IV MAINTENANCE

WARRANTY REPAIRS

Keating’s warranty begins with the date of isntallation.
In the even that your Pasta System, under warranty,
needs repairs other than routine maintenance or
cleaning, you are requested to contact Keating of
Chicago Inc. at 1-800-KEATING before calling a local
service company.

PREVENTIVE MAINTENANCE

Preventive maintenance should be done in daily,
weekly, monthly and yearly intervals as necessary.
Following preventive maintenance procedures will help
keep your Pasta System working efficiently. Proper care
and servicing will lead to years of quality performance. 

NOTE: 

The most important part of any maintenance

program is daily cleaning. Ninety percent of any
maintenance problem is directly or indirectly related to
cleanliness.

NOTE: 

Water level problems caused by the sensors

not being cleaned adequately will not be covered under
warranty.

NOTE: 

Use of sodium chloride during the cooking

process will have a detrimental effect on the cooker
vessel and will void the warranty.

*

High production facilities should be checked more often.

WHEN THE WATER LEVEL FALLS BELOW THE
BOTTOM WATER SENSOR THE HEATING
ELEMENTS WILL TURN OFF. IF THEY CONTINUE
TO HEAT, TURN THE MAIN POWER SWITCH OFF
AND CHECK AUTO-FILL SYSTEM.

LIMITED CALIBRATION 

Calibration is not covered under warranty

A. Calibration

NOTE: 

This procedure can only be used with the

primary (left side) thermostat. When calibrating the
secondary (right side) thermostat you will need:

• One standard flat blade screwdriver.

• One accurate thermometer suitable for boiling water.

NOTE:

For best results, water should be clean.

1.

Set thermostat to 212°F(190°C).

2.

Allow Pasta System to cycle three times.

3.

Place an accurate thermometer in the water.

Figure 4-1: Thermometer in water

NOTE: 

Locate thermometer in same position for

PREVENTIVE MAINTENANCE CHART

TIME FRAME

OPERATOR/OWNER

SECTION

Hourly

• Clean sensor tube with a brush

Daily

• Check lights and controls.
• Check water level.
• Clean all baskets.
• Clean sensor tube with a brush

and vinegar

III

Weekly

• Boil-out Pasta Cooker

(2-3 times/week)

• Drain and clean Pasta Cooker

III

Monthly

• Verify thermostat settings 

(primary and secondary)

IV & V

Yearly

QUALIFIED SERVICE

PERSONNEL ONLY

• Check all wire connections. 
• Replace suspect wires.

IV & V

Содержание 24763

Страница 1: ...KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Part 024763 Electric Pasta 0709 7 09 CUSTOM PASTA SYSTEM ELECTRIC SERVICE MANUAL...

Страница 2: ...nufacturer of all warrant and liability Keating of Chicago Inc manufacturer reserves the right to change specifications at any time IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE C...

Страница 3: ...Calibration 9 10 Auto Fill Safety Shut Off 10 Sensor Tube Cleaning 10 SECTION V SERVICE DIAGNOSIS Auto Fill System 11 Cooker Heating Section 11 Troubleshooting Charts 12 13 SECTION VI PARTS LIST Orde...

Страница 4: ...ic timers Low water safety shutoff 1 full port front drain valve on 14 11 4 for 18 and larger High temperature limit control with manual reset Patented accurate temperature control system 2 F Ideal 35...

Страница 5: ...power panel before servicing NEVER leave a pasta system unattended during operation NEVER move a pasta system when full of hot water NEVER introduce objects or liquids into pasta system while operati...

Страница 6: ...en file a claim with the carrier since such damage is the carrier s responsibility By following these instructions carefully we guarantee our full support of your claims to protect you against loss fr...

Страница 7: ...device or its associated piping to limit the appliance movement Connectors must comply with ANSI Z21 69 CAN1 CAN CGA 6 16 latest edition for connectors for movable gas appliances Quick disconnect devi...

Страница 8: ...difference between the two thermostats Having less than a twenty degree difference will increase the possibility of a boil over and cause the pasta cooker to short cycle The recommended starting tempe...

Страница 9: ...t Lift Model 1 Fill Pasta System as described on page 6 Filling 2 Set primary left thermostat to 212 F 100 C and secondary right thermostat to 190 F 87 8 C 3 Fill basket s to proper level and place on...

Страница 10: ...turn ON and the display will now be indicating OR The BEEPER will BEEP 4 times NOTE If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more...

Страница 11: ...any maintenance problem is directly or indirectly related to cleanliness NOTE Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty NOTE Use of sod...

Страница 12: ...cleaning Control of the water level is fully automatic with the auto fill system The water level is controlled by two circuit boards and two sensors The sensors are located in the tube on the right s...

Страница 13: ...it The potentionmeter adjusts the sensitivity of the probe Adjusting this sensor will not increase the depth of the water Improper adjustments can effect the operation of the cooker and cause damage...

Страница 14: ...not minutes or seconds 1 Reset the timer see pages 8 9 Water leaking in the rear of the pasta cooker 1 Replace fill hose Part 037390 sold per foot Breakers continue to trip 1 Ensure all wires to the c...

Страница 15: ...echanism does not operate a Connections are loose or timer is faulty b Motor limit switch is faulty c Lift motor is faulty d Actuator is faulty e Control circuit fuse has blown f Relay is faulty a Tig...

Страница 16: ...1 Custom Pasta System Electric Control Panel 1 2 3 2 4 5 6 6 7 7 ORDERING PARTS Parts may be ordered by part number by calling Keating at 1 800 KEATING or your local servce company You may also order...

Страница 17: ...SMALL 002565 CIRCUIT BREAKER 40AMP 1P 012129 4 6 6 4 FUSE 300V 3AMP 004334 2 2 2 2 CONTACTOR 110V 3P 50AMP 011225 3 3 3 2 CONTRACTOR 110V 4P 40AMP 005597 1 TRANSFORMER STEPDOWN 004376 1 1 1 1 220 110V...

Страница 18: ...16 VII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS 2...

Страница 19: ...14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM 17...

Страница 20: ...18 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 21: ...19 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...

Страница 22: ...20 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 23: ...21 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Страница 24: ...22 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Страница 25: ...OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installatio...

Страница 26: ...______________ INVOICE NUMBER __________________________ SERIAL NUMBER ______________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ____________________________________ TOP SIDE COOKER HOT PLATE...

Отзывы: