I  INTRODUCTION

Instructions in this manual should be read thoroughly
before attempting to operate this Keating Electric
Pasta Cooker. All installation and service on Keating
Equipment must be performed by qualified, certified,
licensed and/or authorized installation or service
personnel.  

Operating information for Keating equipment has
been prepared for use by qualified and/or authorized
personnel. 

Keating equipment is made in the U.S.A. and has
American sizes of hardware. All meteric conversions
are approximate.

GENERAL

Keating Electric Custom Pasta

Systems are designed

to give maximum production efficiency, delivering high
quality food products. The following design features are
incorporated in Keating Pasta Electric Systems.

STANDARD FEATURES

Highly polished stainless steel vessel

Highly polished stainless steel front

Highly polished stainless steel elements

Highly polished stainless steel thermostat bulb

Highly polished stainless steel Hi-Limit sensor

Grid screen over elements

Automatic water fill with manual override

Water solenoid and indicating light

Starch overflow

Two electronic timers

Low water safety shutoff

1" full port front drain valve on 14; 
1

1

/

4

" for 18 and larger

High temperature limit control with manual reset

Patented accurate temperature control system 
±2°F

Ideal 35" working height

One pair of perforated split baskets or one bulk 
basket

Patented dual thermostat system

Indicating lights for pilot and secondary thermostat
on

STANDARD ACCESSORIES

Keating Klenzer Sample

Drain clean out rod

Sensor Cleaning Brush

STANDARD PASTA SYSTEMS

Sizes:  14” to 24”

Water capacity 5

1

/

2

to 24 gallons

24” Pasta System can cook 6 lbs. of dry pasta per
load up to 110 lbs. per hour

NSF certified

ETL Certified listed

ETL Sanitation Certified listed

MODEL VARIATIONS

Basket-Lift Model:

Basket-Lift Model Pasta Systems

come with all the same features as the standard
models. The Basket-Lift mechanism lowers the baskets
of food into the water when the timer button is pressed
and raises the baskets when the cooking cycle is
complete. Split baskets are required for these models.  

SPECIFICATIONS

MODEL kW @ 240V

AMPS

SHIP WT.

3P

1P

14

15.5

32-56-32

65

140 lbs

18

21.4

52-52-52

89

215 lbs.

20

21.4

52-52-52

89

235 lbs.

24

28.6

79-79-52

119

285 lbs.

MODEL

CAPACITY HEIGHT

DEPTH

WIDTH

14

7 gal.

46

1

/

2

"

31

1

/

8

"

15

3

/

8

"

18

10 gal.

46

1

/

2

"

33

1

/

8

"

19

3

/

8

"

20

17 gal.

46

1

/

2

"

35

1

/

8

"

21

3

/

8

"

24

24 gal.

46

1

/

2

"

39

1

/

8

"

25

3

/

8

"

Содержание 24763

Страница 1: ...KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Part 024763 Electric Pasta 0709 7 09 CUSTOM PASTA SYSTEM ELECTRIC SERVICE MANUAL...

Страница 2: ...nufacturer of all warrant and liability Keating of Chicago Inc manufacturer reserves the right to change specifications at any time IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE C...

Страница 3: ...Calibration 9 10 Auto Fill Safety Shut Off 10 Sensor Tube Cleaning 10 SECTION V SERVICE DIAGNOSIS Auto Fill System 11 Cooker Heating Section 11 Troubleshooting Charts 12 13 SECTION VI PARTS LIST Orde...

Страница 4: ...ic timers Low water safety shutoff 1 full port front drain valve on 14 11 4 for 18 and larger High temperature limit control with manual reset Patented accurate temperature control system 2 F Ideal 35...

Страница 5: ...power panel before servicing NEVER leave a pasta system unattended during operation NEVER move a pasta system when full of hot water NEVER introduce objects or liquids into pasta system while operati...

Страница 6: ...en file a claim with the carrier since such damage is the carrier s responsibility By following these instructions carefully we guarantee our full support of your claims to protect you against loss fr...

Страница 7: ...device or its associated piping to limit the appliance movement Connectors must comply with ANSI Z21 69 CAN1 CAN CGA 6 16 latest edition for connectors for movable gas appliances Quick disconnect devi...

Страница 8: ...difference between the two thermostats Having less than a twenty degree difference will increase the possibility of a boil over and cause the pasta cooker to short cycle The recommended starting tempe...

Страница 9: ...t Lift Model 1 Fill Pasta System as described on page 6 Filling 2 Set primary left thermostat to 212 F 100 C and secondary right thermostat to 190 F 87 8 C 3 Fill basket s to proper level and place on...

Страница 10: ...turn ON and the display will now be indicating OR The BEEPER will BEEP 4 times NOTE If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more...

Страница 11: ...any maintenance problem is directly or indirectly related to cleanliness NOTE Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty NOTE Use of sod...

Страница 12: ...cleaning Control of the water level is fully automatic with the auto fill system The water level is controlled by two circuit boards and two sensors The sensors are located in the tube on the right s...

Страница 13: ...it The potentionmeter adjusts the sensitivity of the probe Adjusting this sensor will not increase the depth of the water Improper adjustments can effect the operation of the cooker and cause damage...

Страница 14: ...not minutes or seconds 1 Reset the timer see pages 8 9 Water leaking in the rear of the pasta cooker 1 Replace fill hose Part 037390 sold per foot Breakers continue to trip 1 Ensure all wires to the c...

Страница 15: ...echanism does not operate a Connections are loose or timer is faulty b Motor limit switch is faulty c Lift motor is faulty d Actuator is faulty e Control circuit fuse has blown f Relay is faulty a Tig...

Страница 16: ...1 Custom Pasta System Electric Control Panel 1 2 3 2 4 5 6 6 7 7 ORDERING PARTS Parts may be ordered by part number by calling Keating at 1 800 KEATING or your local servce company You may also order...

Страница 17: ...SMALL 002565 CIRCUIT BREAKER 40AMP 1P 012129 4 6 6 4 FUSE 300V 3AMP 004334 2 2 2 2 CONTACTOR 110V 3P 50AMP 011225 3 3 3 2 CONTRACTOR 110V 4P 40AMP 005597 1 TRANSFORMER STEPDOWN 004376 1 1 1 1 220 110V...

Страница 18: ...16 VII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS 2...

Страница 19: ...14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM 17...

Страница 20: ...18 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 21: ...19 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...

Страница 22: ...20 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Страница 23: ...21 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Страница 24: ...22 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Страница 25: ...OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installatio...

Страница 26: ...______________ INVOICE NUMBER __________________________ SERIAL NUMBER ______________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ____________________________________ TOP SIDE COOKER HOT PLATE...

Отзывы: