8
B2)
Install Hanger Plate Assembly on Plaster Ceiling /
Ԋ၆ӤݖಢӇ
ՍүᆽЈ߆ݖ
For Plaster Ceiling, static metal structure (welded) must
be prefi x on the concrete ceiling via anchor bolt before
installing the Ceiling Fan
對於石膏天花板,安裝吊扇前,請先利用固定螺栓將靜態
金屬結構(焊接)固定在混凝土天花板上
Installation Note.
1
Ensure Static Metal Structure is fi rmly bolted to the
concrete ceiling as shown in the Figure 1 and able
to withstand weight of 100kg. The Lower Plate of
Static Metal Structure should be the same level as
the plaster ceiling. Allow 5~10mm gap between the
Lower Plate and Plaster Ceiling. Make sure holes are
made on the lower plate of the Static Metal Structure
as shown in Figure 2. (Suggest Lower Plate of Metal
Struture is 260mm X 260mm X 5mm)
2
Bolt the Hanger Plate Assy onto the Lower Plate as
shown in Figure 3. Use M6 Bolts instead of the Carl
Bolt supplied. Ensure there are no loose parts in the
entire hanging structure.
安裝備註。
1
如圖 1 所示,確認靜態金屬結構牢牢地栓在混凝土天花
板上且可承受 100 公斤重量。靜態金屬結構的下模板
應與石膏天花板的高度齊平。下模板與石膏天花板間,
請預留 5
~
10 毫米距離。如圖 2 所示,確認靜態金屬結
構的下模板上有鑽孔。(建議金屬結構的下模板大小為
260 毫米 X 260 毫米 X 5 毫米)
2
如圖 3 所示,將吊板組件栓在下模板上。請使用 M6 螺
栓,不要使用隨附的卡爾螺栓。確認整個吊掛結構中沒
有鬆脫的零件。
Do not install the Ceiling Fan directly onto plaster ceiling.
Can cause Ceiling Fan to drop after long period.
請勿將吊扇直接安裝在石膏天花板上。
長期下來會導致吊扇掉落。
ATTENTION /
ཎ
M5 screw, M6 Bolt, Plain Washer, Spring Washer and Nut are not provide with this product.
The static metal structure is not supplied with this product, please kindly consult with qualifi ed personnel on the static metal
structure design.
本產品未隨附 M5 螺絲、M6 螺栓、普通墊圈、彈簧墊圈和螺帽。
本產品未隨附靜態金屬結構,請向合格的靜態金屬結構設計單位人員洽談。
WARNING /
ឌ֙
Fix Hanger Plate Assembly correctly to the Metal Structure, and tighten Hexa Nut fi rmly.
Can cause Ceiling Fan to drop and cause injuries.
將吊板組件正確地安裝於金屬結構,並鎖緊六角形螺帽。
這可導致吊扇掉落和導致受傷。
60°
110mm
4-Ø6
Ø5
1
2
3
4
5
60°
Ø94
260
260
Concrete Ceiling /
混凝土天花板
Check Point After Installation /
Ԋ၆ࡣޟᔮᡛᘈ
1. Ensure the Hanger Plate Assembly is securely fi xed on the Metal Structure. The Bolt, Plain Washer,
Spring Washer and Hexa Nut should be fi rmly tightened for safety reasons. /
確定吊板組件已鎖緊在金
屬結構。基於安全理由,螺栓、普通墊圈、彈簧墊圈及六角形螺帽必須鎖緊。
Check /
ᔮࢥ
Gap between Lower
Plate & Plaster Ceiling
10mm /
下模板和石
膏天花板之間距離
10 毫米
Lower Plate /
下模板
( 260mm ) /
( 260
毫米
)
Plaster Ceiling /
石膏天花板
Hanger Base /
吊架底部
Lower Plate of Metal Structure /
金屬結構的下模板
Static Metal Structure /
靜態金屬結構
M6 Bolt /
M6 螺栓
Hole for Safety
Wire /
保險線孔
Hexa Nut /
六角形螺帽
Safety Wire /
保險線
Hanger Plate Assy /
吊板組件
Spring Washer /
彈簧墊圈
Plain Washer /
普通墊圈
M5 Screw /
M5 螺絲
Lower Plate /
下模板
Bolt, Spring Washer and Plain Washer and Nut /
螺栓、彈簧墊圈、普通墊圈和螺帽
Figure 2 /
圖
2
Figure 4 /
圖
4
Figure 3 /
圖
3
Figure 1 /
圖
1
R48SP.indd 8
R48SP.indd 8
4/15/2013 5:20:42 PM
4/15/2013 5:20:42 PM